Rev. 1.1
Digital Multi-Purpose Controller 97TS500R
Page 14 of 20
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
6.3.2 Program Selection
1. Press the "Set" button (3) to mark the selected program number.
2. Use the (+) or (-) button to select the desired program.
3. Press the "Set" button (3) to end.
6.3.3 Setting the Manual /"Purge" Dosing Cycle:
1. Increase the air pressure by turning the compressed air controller (6) until the desired pressure is
shown on the display.
2. Press the mode button (2) until
“PURGE” appears in display.
3. Hold down the foot switch in order to activate the manual cycle.
4. Hold the
“Set” button (3) for two seconds to change into the Setup-display. The engine reverse time will
be marked.
5. Use the buttons (+) and (-) to set the engine reverse time.
6. Hold the
“Set” button (3) for two seconds to move the cursor to the output voltage.
7. Use the buttons (+) and (-) to set the voltage.
8. Hold the
“Set” button (3) for two seconds to save the data.
9. Hold the foot switch in order to activate the manual cycle.
6.3.4 Setting the Automatic Dosing Cycle:
1. Press the mode button (2) and select from the modes "TIMED MODE" (time-operated) a
nd “INTER-
RUPT”(step-operated).
2. Press and hold the
“Set” button (3) for two seconds to change into the Setup-display. The dosing time
(DISP) will be marked.
3. Use the buttons (+) and (-) to set the time.
4. Hold the
“Set” button (3) for two seconds to move the cursor to the engine reverse time.
5. Use the buttons (+) and (-) to set the reverse time.
6. Use the
“Set” button (3) to move the cursor to the next position.
7. Hold the
“Set” button (3) for two seconds to move the cursor to the output voltage.
8. Use the buttons (+) and (-) to set the voltage.
9. Hold the
“Set” button (3) for two seconds for saving the data.
10. If the device operates in "TIMED MODE" (time-controlled), push foot switch and let go in order to acti-
vate the time-controlled dosing cycle.
11. If the device is in "INTERRUPT" mode (step-operation), push foot switch and hold until dosing cycle
has finished. Let foot switch go in order to interrupt the dosing cycle and push again in order to reacti-
vate.
NOTE!
Please follow the below instruction for a correct setting of the engine reverse time and the
output voltage.