Rev. 1.1
Assembly Instructions - Spray Valve SMS-13
Page 9 of 26
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
7 Taking out of Service
7.1 Short Interruption
A short interruption (15 min and more) will always be followed by a clean-spraying.
NOTE
Please follow the operating instructions!
7.2 Long-term Interruption
The following steps will be observed for a long-term interruption of the device/machine:
Depressurize material supply lines
Remove retainer ring (1) and clean airless-nozzle with a special thinner and a soft cloth. Make sure
that no cloth fibers are left on the nozzle tip.
NOTE
Please follow the maintenance instructions!
7.3 Shutdown of Device
The following is important for a shutdown of the machine / device:
Clean airless spray valve with a special thinner.
NOTE
Please follow the maintenance instructions!