![WALTHER PILOT GM 1030G Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/walther-pilot/gm-1030g/gm-1030g_translation-of-the-original-operating-manual_3289253025.webp)
25
OPERATING MANUAL
EDITION 11/2022
ORDER NUMBER DOC
2428311
PILOT GM 1030G
8.2.2 SAFETY INSTRUCTIONS
DANGER
Improper Maintenance/Repair!
Danger to life and equipment damage.
Only a WALTHER service center or a suitably trained person may carry out repairs
and replace parts.
Use only WALTHER original spare parts and accessories.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the device.
Before all work on the device and in the event of work interruptions:
- Relieve the pressure from the spray gun, product hoses and all devices.
– Secure the spray gun against actuation.
– Switch off the energy and compressed air supply.
Observe the operating and service manual for all work.
Prior to maintenance
– Flush and clean the system as described in Chapter
8.1.3
.
After maintenance
1. Carry out a safety check as described in Chapter
8.2.3
.
2. Put the system into operation and check for leaks as described in Chapter
6.8
.
3. Perform function test as described in Chapter
11
.
4. Have the system checked for safe condition by a skilled person.
8.2.3 SAFETY CHECKS AND MAINTENANCE INTERVALS
Every day
Check grounding: see Chapter
6.5
Check hoses, tubes and couplings: see Chapter
8.2.4
Flush and clean the spray gun as described in Chapter
8.1.3
.
Weekly
Check spray guns for damage.
Yearly or as required
In accordance with DGUV regulation 100-500, Chapter 2.29 and 2.36:
– The liquid ejection devices should be checked by an expert (e.g., a WALTHER
service technician) for their safe working conditions as required and at least
every 12 months.
– For shut down devices, the examination can be suspended until the next start-
up.
8.2.3.1 PRODUCT HOSES, PIPES AND COUPLINGS
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
Check hoses, pipes, and couplings every day and replace if necessary.
Before every commissioning, check all connections for leaks.