background image

 TPAK Series

COOLANT PUMP

Instruction Manual

ISO 9001 Certified

WALRUS PUMP CO., LTD.

Содержание TPAK Series

Страница 1: ...TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO LTD ...

Страница 2: ...l TPAK Series Conform to the following directive 2006 42 EC Machinery directive 2014 35 EU Low voltage directive 2014 30 EU EMC Electromagnetic compatibility directive Refer to the following standards EN ISO 12100 2010 EN ISO 13857 2008 EN 809 1998 A1 2009 EN 60204 1 2006 EN 60335 1 2012 EN 60335 2 41 2003 EN 61000 6 2 2005 EN 61000 6 3 2007 R D department manager Kao Tien chuan Manager ...

Страница 3: ... 2 Model Code 3 Operating Limits 1 Ambient temperature Max 40 C 2 Liquid temperature range 0 C to 90 C 3 Operating pressure Max 10 kg cm 4 Head 50Hz Up to 12M 60Hz Up to 17M 4 Installation The pump has hot surface on the motor It must be installed so that persons cannot accidentally come into contact the hot surface 4 1 Pump location Note The pumps can only be mounted in vertical position see fig ...

Страница 4: ...n phase protector to avoid motor damage 6 Start up Before starting the pump make sure the following 6 1 For three phase motors verify if the rotating direction is correct It should be clockwise look down from the motor fan cover 6 2 All piping joints are completely tight Leakage in piping may cause the pump hydraulic loss 6 3 The pump is filled with liquid 6 4 The suction filter is not blocked by ...

Страница 5: ...tricity supply b Fuses are blown c Motor overheating relay tripped d Defective magnetic contactors e Control circuit malfunction 10 2 Motor cut out during operation a Fuses blown or breakers tripped b Overheating relay tripped c Control circuit malfunction d Pump locked up by foreign objects 10 3 Pumped capacity is not constant a Pump impeller blocked by impurities b Insufficient liquid level in t...

Страница 6: ...175 24 Rp 80 112 5 Ø120 Ø120 160 4xØ8 PCD158 10 6 TPAK 4 15 385 150 235 28 Rp 85 111 Ø135 Ø135 170 4xØ9 PCD170 11 2 TPAK 4 18 415 180 235 28 Rp 85 111 Ø135 Ø135 170 4xØ9 PCD170 11 9 TPAK 4 25 485 250 235 28 Rp 85 111 Ø135 Ø135 170 4xØ9 PCD170 12 7 TPAK 8 18 456 180 276 29 Rp 1 95 111 Ø150 Ø150 190 4xØ9 PCD185 15 5 TPAK 8 25 526 250 276 29 Rp 1 95 111 Ø150 Ø150 190 4xØ9 PCD185 17 1 TPAK 15 25 573 2...

Страница 7: ... 3 50 270 200 255 380 440 1 0 1 3 0 6 0 8 60 350 200 255 380 480 1 2 0 7 TPAK 4 3 50 440 200 255 380 440 1 5 1 9 0 9 1 2 60 620 200 255 380 480 2 0 1 1 TPAK 8 3 50 930 200 255 380 440 3 1 4 4 1 9 2 6 60 1320 200 255 380 480 4 0 2 4 TPAK 15 3 50 1300 220 380 4 8 2 8 60 2000 220 380 5 4 3 1 ...

Страница 8: ...omply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation inappropriate chemicals or additives in the water inadequate protection against freezing rain or other adverse weather conditions corrosive or abrasive water lightning or high voltage spikes or through unauthorized persons attempting repairs are not covered under warranty Walrus ...

Отзывы: