XII. Frequently asked questions:

1. What causes the TQ to start?

  The TQ has the built-in pressure switch and internal flow switch. Each of these can turn 

the pump on depending on water consumption. The pump will start when:

- The pressure is BELOW the pressure switch activation point. OR

- The flow rate is greater than 0.7 GPM.

  The preset activation point for each model is provided in the pump specifications. 
2. What causes the TQ to stop?

   The flow switch is designed to automatically stop the TQ pump when flow drops to below 

0.7 GPM. The pump will shut off in a few seconds after flow stops (TQ1500-3700 is 

programmed to stop after 15 seconds). In addition, the TQ will be turned off in the event 

of dry-run or over temperature alarm.

 3. What is the purpose of the built-in pressure tank?

The pressure tank comes from the factory pressurized at approximately 43 psi (with the 

pump pressure at zero). It is designed to minimize motor startup due to small flow 

demand or minor leak of the pipeline. 

4. How is the dry-run condition determined and the protection provided?

The dry-run is defined when the motor is running AND the flow rate is less than 0.3 GPM 

AND when pressure is less than the pressure switch setting. The protection is provided: 

When the pump is run dry 2 minutes, it will automatically shut off for 10 minutes and 

then attempts to restart. When all 3 attempts are failed, the pump will rest for 1 hour 

and then attempts to restart. This protection mode will be repeated until the water 

supply is back to normal. 

In case the pump is cycling (on-and-off repeatedly) due to small flow (less than 

0.3GPM), air pocket in the system, air loss in the pressure tank or leak in the pipeline, 

the protection is provided:

The pump will run for 8 seconds and stop for about 3 seconds. When the cycling mode 

repeat for 15 times consecutively, the pump will be rest for 1 hour.  Then it will start over 

the protection mode until the problem is corrected.

Note: The pump can be reset anytime by removing the power plug.

5. What is the maximum inlet pressure allowed in the TQ?

The maximum internal system pressure allowed for TQ is 120 psi. The maximum inlet 

pressure when added to the TQ pressure must not exceed 120 psi. 

Additionally, if inlet pressures exceed the built-in pressure switch activation point (43 

psi factory default), the pressure switch will be unable to function, and the ability to turn 

the TQ on at low flow rates will be lost. In this situation, only the flow switch will be able 

to turn the TQ on at flow rates above 0.7 GPM.

Содержание TQ Series

Страница 1: ...ELECTRONIC CONTROL PUMP Model 1500 2200 3700 To ensure safe and proper use please read this instruction before operation ISO 9001 Certified Walrus America Inc Instruction Manual NSF ANSI 372 TQ Series...

Страница 2: ......

Страница 3: ...p Model TQ Series Conform to the following directive 2006 42 EC Machinery directive 2014 35 EU Low voltage directive 2014 30 EU EMC Electromagnetic compatibility directive Refer to the following stand...

Страница 4: ...d to the foundation 2 It is recommended that the plumber install er provides an adequate draining system to avoid damage in case of leakage particu larly when installed indoors When it is installed ou...

Страница 5: ...as the suction pipe it must be non collapsible 5 To minimize pressure drop the discharge pipe should be at least the same size as the discharge port of the pump 6 For long suction pipes or high sucti...

Страница 6: ...es not require any adjustment Whenever the installation position of the pump is higher than 3ft above the lowest water level a foot valve must be installed on the end of suction pipe Warning The pump...

Страница 7: ...G Risk of electric shock This pump has not been investigated for use in swimming pool or marine areas To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle...

Страница 8: ...f the pump is to be inactive for long periods it should be rinsed thoroughly with clean water then drained and stored in a dry place It has to be re primed before start up 4 Pressure tank air charge s...

Страница 9: ...e psi 10 20 30 40 60 gpm 27 37 47 57 TQ2200 Flow rate 10 gpm 66 76 86 96 20 gpm 62 72 82 92 30 gpm 58 68 78 88 40 gpm 53 63 73 83 50 gpm 46 56 66 76 Inlet pressure psi 10 20 30 40 60 gpm 36 46 56 66 T...

Страница 10: ...ssure is less than the pressure switch setting The protection is provided When the pump is run dry 2 minutes it will automatically shut off for 10 minutes and then attempts to restart When all 3 attem...

Страница 11: ...Q max GPM 66 0 71 3 71 3 Amp s A 9 5 or 6 5 9 5 12 Preset activation pressure psi 43 43 43 Max discharge pressure psi 58 60 72 Model TQ1500 2200 3700 17 8 5 59 6 42 9 06 6 3 8 66 8 66 10 63 14 76 10...

Страница 12: ...b Defective check valve a 3 phase motor runs in wrong rotating direction b Poor water supply Remedy Connect the electricity supply Check if supply voltage is within 10 Open a tap Place a screwdriver...

Страница 13: ...g instructions Failure to comply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation inappropriate chemicals or additives in the water ina...

Страница 14: ......

Страница 15: ......

Страница 16: ...Walrus America Inc CP70D0006D600UW0R03 05 walrusamerica com...

Отзывы: