L= Length (mm), W = Width (mm)
WORKLOAD LIMIT FOR PLATES (FOR S 235 JR [ST 37])
© Copyright 2014: WALMAG MAGNETICS
All rights reserved. No part of this publication
may be duplicated and/or made public by means
of printing, photocopying, microfilm or in any
other manner whatsoever without prior written
permission from WALMAG MAGNETICS. This
also applies to all accompanying drawings and
illustrations.
Do not lift plates thinner than
indicated in the chart!
Horizontal
∆
=
˂
0,1 mm
∆
= 0,1 - 0,3 mm
∆
= 0,5 mm
s (mm) Lmax x Wmax
(mm)
Mmax
(kg)
Lmax x Wmax
(mm)
Mmax
(kg)
Lmax x Wmax
(mm)
Mmax
(kg)
˃
20 1600 x 1000 250 1000 x 700 115 500 x 500
45
12 2000 x 1000 195 1500 x 800 110 1000 x 500 45
10 1700 x 1000 140 1200 x 800 75 1200 x 500 45
8 1100 x 1000 95 1200 x 800 60 1200 x 500 38
5 1500 x 1000 60 1000 x 800 33 1200 x 500 23
3 1700 x 1000 40 1300 x 800 25 1500 x 500 19
Vertical
∆
=
˂
0,1 mm
∆
= 0,1 - 0,3 mm
∆
= 0,5 mm
s (mm) Lmax x Wmax
(mm)
Mmax
(kg)
Lmax x Wmax
(mm)
Mmax
(kg)
Lmax x Wmax
(mm)
Mmax
(kg)
˃
20 1000 x 500 80
500 x 400
30
400 x 300
12
12 1200 x 500 60
600 x 500
28
400 x 300
11
10 1200 x 500 46
500 x 500
20
400 x 300
10
8
1000 x 500 30
500 x 500
15
400 x 300
8
5
1000 x 500 18
500 x 400
8
500 x 300
6
3
1000 x 500 13
500 x 500
6
500 x 400
5
Weekly:
Check the entire magnet, including the lifting
eye and release handle, for deformations,
cracks or other defects. If the lifting eye is
deformed or worn off for more than 10%,
it should be replaced. Check the presence
and legibility of the type plate and instruction
plate. Check the pole shoes. If they are
damaged more than 10% (pits, burrs etc.) the
magnet should be returned to your supplier
or an authorised agent for regrinding. Lifting
capacity is checked following this operation.
Annually:
Have the lifting capacity of your magnet
checked by your supplier or an authorised
agent at least once a year in accordance
with the European standard EN 13155.