background image

 

 

 

 
 
 
 
 

 

 
 
 
 
Product Manual 

WHBV-101W-LH-NB and 
WHBV-101W-RH-NB 
Washbasin with Integral 
Tap

Содержание WHBV-101W-LH-NB

Страница 1: ...Product Manual WHBV 101W LH NB and WHBV 101W RH NB Washbasin with Integral Tap...

Страница 2: ...Revision 5 2 Product Manual WHBV 101W LH NB and WHBV 101W RH NB...

Страница 3: ...2 5 Menu items 5 3 Glossary 6 4 Overview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 2 1 Mounting Guidelines 7 5 3 Preparing the Washbasin 12 5 4 Mounting the...

Страница 4: ...NZS 3500 the PCA and your local regulatory requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provis...

Страница 5: ...ngs before you install and commission the wash basin Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is us...

Страница 6: ...r anti ligature products have been designed to reduce the likelihood of a ligature attachment however it is the responsibility of the purchaser or service provider to ensure it is risk assessed and su...

Страница 7: ...ation 5 2 Site Preparation 5 2 1 Mounting Guidelines The washbasin must be attached to a vertical surface that can support the weight of the washbasin See Table 1 on page 16 for the weight Refer to Fi...

Страница 8: ...Revision 5 8 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 1 WHBV 101W RH NB Basin Details...

Страница 9: ...Revision 5 9 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 2 WHBV 101W LH NB Basin Details...

Страница 10: ...Revision 5 10 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 3 Wall hole sizes positioning for WHBV 101W RH NB...

Страница 11: ...Revision 5 11 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 4 Wall hole sizes positioning for WHBV 101W LH NB...

Страница 12: ...aptor Item 8 figure 5 into the integral push fit connection on the basin inlet and attach a water supply pipe The water supply connection is provided on site by others Site conditions and the type of...

Страница 13: ...Revision 5 13 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 5 Components and assembly details for the WHBV 101W RH NB...

Страница 14: ...pective holes in the brackets Item 2 figure 5 3 Once the positions have been checked make sure the basin seats flush against the wall The side support angle brackets Item 2 figure 5 can be adjusted fo...

Страница 15: ...ebris and trapped air NOTE Fit a Y strainer in the water supply feed pipe before connection to the washbasin especially on older installations where loose particles from ageing water pipes can cause a...

Страница 16: ...rged from the system and to ensure that the flow rate is correct 5 7 Technical Specifications Table 1 Technical specifications Weight Approximately 35Kg Dimensions 720mm W x 310mm H x 440mm D Water Su...

Страница 17: ...n be obtained from our customer service department 6 1 Maintenance General wear mainly affects the components in contact with water If the unit is installed in a hard water area lime scale may need to...

Страница 18: ...the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the M...

Страница 19: ...el 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com Galvin Engineering Pty Ltd 410 Victoria Road Malaga Western Australia 6090 Australia tel 61 8 9338 2344 fax 61...

Отзывы: