background image

 

Revision 7 

14 

 

Product Manual PSH-23

 

and is activated by lightly pressing on the centre of the button with your finger tip. 
Once the cycle is activated it will run for 6 seconds and stop. 

3.  If the time cycle of 6 seconds requires to be adjusted, then this can be done by 

referring to the product manual for the electronic control unit model that is 
installed. Note that the electronic control includes a function called “LOCKOUT” 
which is to 

prevent misuse of the wash basin. The “LOCKOUT” function permits 

one operation of water in a 15-minute period and locks out the unit for a 15-
minute period after the last operation of water. The setting for this function can be 
adjusted as required or it can be disabled. Further assistance with this can be 
supplied by contacting Wallgate at the telephone number stated above. 

4.  The electronic control unit only activates the water ON or OFF and does not have 

any affect with the water temperature which would be controlled before this 
product as a part of the plumbing installation. 
 

8.2. 

Maintenance 

 

  Wallgate operates a comprehensive service package, details of which can be 

obtained from our “After Sales Service Department”. A full spare parts facility 
is also available. 

  General wear will mainly affect the components in contact with the water 

dispensing and the basin waste outlet. If the unit is installed in a hard water 
area, then lime scale removers should be used on the basin and water nozzle 
components.  

  The water nozzle can be dismantled and immersed in a de-scaling solution for 

cleaning. The basin waste is fitted with a grille which shall require regular 
cleaning to remove build-up of soap residue, hairs, lime scale etc.  

  A cleaning brush is provided to assist in cleaning between the grille vanes 

which must be done on a regular basis depending upon product usage. Spare 
parts can be obtained as shown in the spares list table (page 15). 

  Any service or repair work must be carried out by a qualified engineer, which 

during the warranty period must be a Wallgate engineer or appointed service 
agent. Contact Wallgate to report any warranty breakdowns. 

 
 
 
 
 
 
 

Содержание PSH-23

Страница 1: ...Product Manual PSH 23 Hand Wash Basin with Integral Tap ...

Страница 2: ...Revision 7 2 Product Manual PSH 23 ...

Страница 3: ...verview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 3 Mounting the control unit and basin 8 5 4 Water Supply Connection 11 5 5 Waste outlet connection 11 5 6 Electrical supply connection 12 6 Commissioning for Use 12 7 Technical Specifications 13 8 Use and Maintenance Instructions 13 8 1 Operation 13 8 2 Maintenance 14 9 Related Documentation 15 ...

Страница 4: ...ny time without prior notice This manual is specific to the product that it has been supplied with at the date of supply Without prejudice to any warranties in Wallgate Limited s terms and conditions of sale any warranty will be invalidated if the equipment is installed or serviced by unqualified personnel No part of this publication and the information contained may be reproduced transmitted stor...

Страница 5: ...ou install and commission the basin Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is used to draw your attention to important and useful information NOTE This is a note 2 3 Numbered procedures Steps in procedures are numbered starting from 1 1 This is step 1 2 This is step 2 etc 2 4 Bullet lists 1 A bul...

Страница 6: ...d in the PSH 23 to operate the hand wash function BSP The British Standard Pipe BSP thread is a family of standard screw thread types that has been adopted internationally for interconnecting and sealing pipe ends by mating an external male with an internal female thread 1 Push fit Push fit type fittings are a plumbing pipe connector that pushes onto the copper tube and has an integral rubber seal...

Страница 7: ...from floor level should be positioned to suit the user typically 850mm gives a height of 1m to the basin opening lower edge 2 The electronic control unit Sold as a separate option various models are available contact Wallgate sales office must be permanently fixed to the wall and positioned above all water pipes and fittings as shown on the drawing INS_PSH_23 Figure 1 The control box has fixing po...

Страница 8: ...inimum of 33mm and then tighten each stud to a torque of 6Nm 3 Position the basin into the wall aperture and fit the two wall brackets to the M10 studs ensuring correct orientation of each bracket as shown on drawings pages 9 and 10 4 Fit a washer and nut to each threaded stud hand tight only so that the position of the basin can be checked to ensure it is level horizontally and vertically It is a...

Страница 9: ...Revision 7 9 Product Manual PSH 23 Figure 1 PSH 23 INSTALLATION DRAWING ...

Страница 10: ...Revision 7 10 Product Manual PSH 23 ...

Страница 11: ...ump may be required to meet requirements 5 Cables 4m are provided with the solenoid valve for connection to the electronic control unit 6 It is advisable to fit a Y strainer in the feed pipes prior to the unit connection especially on older installations where loose particles from the ageing pipes may cause a blockage on the solenoid valves 7 Isolating taps fitted on the supply feeds local to the ...

Страница 12: ...ry set for water run time durations and lock out settings which deter misuse of the basin The factory settings can be adjusted by the customer or installer if required The unit is supplied as standard with the lockout function DISABLED to allow commissioning to be completed and for the end client to select it if required Refer to the control unit product manual for instructions to set lockouts to ...

Страница 13: ...ions The PSH 23 water dispenser has been designed and manufactured from quality materials If these instructions are followed the unit will give reliable efficient service The installer must pass these instructions to the customer 8 1 Operation 1 The unit is switched ON and OFF by the main isolation switch provided by the installer and positioned in the maintenance duct adjacent to the electronic c...

Страница 14: ...d be controlled before this product as a part of the plumbing installation 8 2 Maintenance Wallgate operates a comprehensive service package details of which can be obtained from our After Sales Service Department A full spare parts facility is also available General wear will mainly affect the components in contact with the water dispensing and the basin waste outlet If the unit is installed in a...

Страница 15: ... information on this control unit refer to the WDC100 product manual WDC200 For more information on this control unit refer to the WDC200 product manual WDC400 For more information on this control unit refer to the WDC400 product manual Part Number Description ES6803_4m Piezo touch button WF3099 Water nozzle WW4004 Waste grille BRUSH01 Waste grille cleaning brush ...

Страница 16: ...Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...

Отзывы: