Installation & Commissioning 

Model FMA. 

 

CONTENTS 

  

Ensure the following items are in the box on unpacking: 

1 x FMA Handwash Unit. 

1 x Foot control panel, (only with FMA-22 & FMA-24 models). 

1 x 1 ltr soap container - 2 x Door keys. 

1 x Product manual. 

 

1. SITE PREPARATION 

a)  Study the installation drawing INSFMA & the following instructions carefully prior to 

commencing any work as this will assist you to plan all aspects. 

b)  Prepare an opening in the wall surface, accurate to the dimensions shown on the installation 

drawing INSFMA. It may be preferable to build a stud wall to house the unit as an alternative 
method if it is not desirable to carry out extensive alterations to the existing wall. A timber 
lining fitted into the aperture will provide greater accuracy in brick/block walls. 

c)  A small aperture is also required for fitting the foot control panel box for the FMA-22 & FMA-

24 models. An enlarged version of this control panel is also available which acts as a 
service access panel. It is advisable to provide an access panel below the main aperture for 
access to the water supply & waste connections if access to these from the opposite side of 
the wall is not possible. 

d)  The unit is not designed to provide support above the opening. If this is required then a 

suitable lintel should be provided. 

e)  An electrical supply should be provided with a switched fused spur - 13amp, double pole 

connection point that is local to the unit (the contact separation of the fused spur switch 
should be at least 3mm). The cable from the switch to the unit should be of minimum 
conductor size 1.5mm sq and should be fitted ready for connection to the Handwash unit. 

f)  A mains cold water supply with a min pressure of 1.75bar should be provided within the 

cavity on the left hand side below the aperture and terminated with a suitable isolating tap. It 
will not be possible to access the isolating tap through the Handwash unit so a means of 
access must be provided or alternatively, position it elsewhere but not too distant from the 
unit. Final connection to the Handwash unit water inlet (15mm compression) may be made 
with a flexible mains rated hose. 

 

IMPORTANT!

 The installer should seek further advice from the manufacturer when 

considering connection to gravity fed systems. The units are designed and approved for 
mains water supply connection. 

 

g)  A waste outlet pipe should be provided within the cavity below the aperture by the installer 

that is of 1 1/4” size. Final connection to the Handwash shall be to the deep seal waste trap 
outlet provided or to the optional decontamination heated waste trap. As with the water 
supply connection it is advisable to consider access to the waste pipe in order to simplify the 
final connections.

 

 
 
 
 
 
 

Содержание FMA 22

Страница 1: ...cts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com PRODUCT MANUAL Handwash Drier MODELS FMA_22 24 25 26 ...

Страница 2: ... suitable lintel should be provided e An electrical supply should be provided with a switched fused spur 13amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm The cable from the switch to the unit should be of minimum conductor size 1 5mm sq and should be fitted ready for connection to the Handwash unit f A mains cold wa...

Страница 3: ...d two each side If a gap exists between the aperture sides and the cabinet then packing pieces should be inserted to prevent distorting the sides of the cabinet 3 ELECTRICAL CONNECTION WARNING This Appliance must be Earthed a The FMA Handwash unit is designed only for fixed wire type installation b The unit should be installed by a qualified electrician in accordance with the current Nationally Ap...

Страница 4: ... a Open fully the mains water supply tap and the water inlet control valve on the unit Check the system carefully for possible leaks b Switch ON the main electrical supply to the unit and then also on the unit itself at the switch located on the left side at the front of the cabinet DANGER Components within the cabinet are now LIVE c Close the door panel and then refer to the USER MAINTENANCE INST...

Отзывы: