background image

Driving eMobility

9/12

Instruction manual

 

10 DISPOSAL

 Please note that this product must not be disposed 

of with household waste. The product must be dispo-
sed of at a designated collection and return point for 
the disposal and recycling of electrical and electronic 
equipment. Observe all applicable national and local 
legislation. Further information can be obtained from 
your local authorities. 

For safety reasons, the charging station may only be 
dismantled by a qualified electrician or a wallbe® spe-
cialist partner. Ask your contact person whether he will 
take charge of the disposal for you.

 

11  TECHNICAL DATA

POWER CLASS 22 kW

Construction type

Charging column

Number of charging 

points

2

Charging capacity

32 A, 400 V, 3-phase

Dimensions 

charging column 

(H x W x D)

270 x 536 x 330 cm

Weight  (charging column 

with roof)

approx. 2 t

Storage temperature

-30 to +70°C

Operating temperature

-25 to +55°C

Relative humidity

30 to 95% (non-condensing)

Protection degree

IP54

Charging socket

2x charging socket type 2 

(

Additionally available:

 shockproof 

socket)

Power contactor

4-pole, 40 A

Control fuse

1-pole, B6

Integrated 

safety devices

RCM-module – 

DC fault current detection. 6 mA

contactor monitoring

Lock release module

RCD

(must be installed in the 

sub-distribution)

Type A

0,03 A / 40 A

Circuit breaker

Not integrated

Authorization

RFID,

App

Housing lockable

Optional

Energy meter

Yes

Protocols

Modbus TCP/RTU, OCPP 1.6J

Interfaces

Ethernet RJ45, RS485, GSM/UMTS

Protection class

1

Содержание Sun4Charge

Страница 1: ...Driving eMobility wallbe Charging station Sun4Charge Online M2M Charging column 2x 22 kW INSTRUCTION MANUAL 110021 c 01 2020...

Страница 2: ...gingprocess 5 4 3 1 Types of authorization 5 4 3 2 Starting the charging process with RFID chip or RFID card 5 4 3 3 Starting the charging process via app 5 4 4 Ending the charging process 5 4 4 1 End...

Страница 3: ...shall not use the charging station without the supervision or instruction of a responsible person 2 SAFETY 2 1 Signal words WARNING Indicates a hazard with a medium le vel of risk which if not avoided...

Страница 4: ...be accepted for damage during trans port if the product is transported in anything other than the original packaging At all times observe the local safety regulations for the country in which you ope...

Страница 5: ...t The charging station is then activated The status LED flashes alternately green and blue After suc cessful activation the charging process starts auto matically The status LED now shines blue 4 3 3...

Страница 6: ...le in your vehicle or plug the charging plug into the parking position You can clean the charging station as follows Wipe the outside of the charging station with a dry cloth WARNING The charging stat...

Страница 7: ...port see chapter 8 After plugging in the charging cable the status LED lights up red immediately The charging cable has a too low current carrying capacity Use a charging cable with a higher current c...

Страница 8: ...y the changes will not be reimbursed 5 Excluded from the guarantee are The cost of regular inspections maintenance re pair or replacement of parts due to normal wear and tear Transport and travel cost...

Страница 9: ...Construction type Charging column Number of charging points 2 Charging capacity 32 A 400 V 3 phase Dimensions charging column H x W x D 270 x 536 x 330 cm Weight charging column with roof approx 2 t S...

Страница 10: ...nterruption of the charging process and the maximum available charging current Circuit breaker Circuit breakers disconnect the circuit from the mains if the current exceeds a certain value due to over...

Страница 11: ...Driving eMobility 11 12 Instruction manual...

Страница 12: ...s reserved This document may not be copied in whole or in part or reproduced in any form or form without the written permission of wallbe GmbH All illustrations in this manual are only examples and ma...