OE?SERVAlIONS

1) Before installing the B-23 fan unit make Sure  that the vol-

tage (V) and the frequency (Hz) indicated on the rating
label correspond to the voltage and frequency of the

mains supply at the Point  of installation.

2) The  rating label and technical data are located in the inte-

rior of the product.

3) This fan unit is supplied with all accessories required for

wall or window installation.

4) The electricaf installation must include a Single-pole swith

with a distance between contacts of at least 3 mm.

5) The  B-23 fan is a class  II appliance and does not require

any earth connection.

6) If you observe any darnage to the product on purchase or

it does not function correctly, use the enclosed guarantee
certificate  and present it, together with proof of purchase,

to any of our authorized technical Service centres.

WALL OR WINDOW  INSTALLATION

1) Cut a hole as indicated in diagram (1).

 

 

 

 

 

 

 

DIAGRAM (1)

2) Dismantle the fan unit by proceeding as follows:

2-l Remove the screws from the front grille (A) to release it

from the body of the fan unit (B).

2-2 Loosen the 4 screws that fix the fan body (B) to the win-

dow support  ring (C).

3-2 Place the window support ring (C) on the inside of the

glass and screw it to the window supporl plate  (D) using
the 4 screws (F).

2-3 Remove the 4 screws that join the two intermediate win-

dow support plates (0) and the window support ring (C).

3-l Place the window support ring (D) and the rear grille in

the hole made in the glass or partition from the rear and
fix it in place using the tabs (E) (there are clasps on the

glass support) to finly anchor  the window support in the
hole.

4-1 Place the body of the fan unit (B) in Position  and screw it

to the window support ring (C) using the 4 screws (G).

4-2 Remove the cover from the cable  entry (H) and carefully

cut a suitable hole in it. Thread  the connection cable
through the hole until it reaches the connection box
cover (1).

4-3 Remove the screws (J) from the connection box cover (1)

and connect the cable to the terminal Strip (K) as shown
in the corresponding wiring diagram.

4-4 Position the covers  on the cable  entry Point (H) and the

connection box (1) and replace the screws (J).

4-5 Replace the front grille (A) and fix it in place using the 4

screws (L).

WALL 

ASSEMBLY

2-l Remove the 4 screws from the front grille (A) to free it

from the fan body (B).

2-2 Loosen the 4 screws that fix the fan body (B) to the win-

dow support  ring (C).

2-4 Place the glass support  mounting ring(C) on the wall and

fix it in place by inserting the 4 screws (M) through the
holes provided in the mounting ring. Make sure  that the
mounting ring is placed  so that the holder (0) is upper-
most as it will then anchor the fan unit body (B).

4-1 Place the fan body (B) in position and screw it to the win-

dow supporl ring (C) using the 4 screws (G).

4-2 Remove the cover from the cable entry (H) and carefully

tut a hole in it. Thread the connection cable through the
hole until it reaches the connection box cover  (1).

4-3 Remove the screws (J) from the connection box cover (1)

and connect the cable to the terminal Strip (K) as shown

in the corresponding wiring diagram.

4-4 Position the covers  on the cable entry Point (H) and the

connection box (1) and replace the screws (J).

4-5 Replace the front grille (A) and fix it in place using the 4

screws (L).

The B-23 fan unit has several modes of Operation:

Exhaust (3 Speeds)
Intake  (3 Speeds)

Fan stopped with only the shutters open.

The shutter opening is controlled  by a delay timer.  They take
about  20 seconds to fully open after power is connected to
the motor.

Fan operated  by a Sensor.
All these possibilities of the fan unit are only available if fitted

with a RB 23/30  swich.
When connecting the Automatic  model of the B-23 fan unit,

the humidity detector  must be fitted inside the fan unit, under
the cover (P). (Fig. 4-2).

8-23 WITHOUT  HYGRO  FITTED WITH RB 23/30

SWITCH DIAGRAM 6

4 wires from the RB 3 30 switching unit to the connection

in the B-23 fan (connection cover

 -

 Strip)  as shown in dia-

gram B). The RB 23/30 switch  also requires two power

supply cables and an earth connection to eliminate any inter-
ference.

-

 As the Hygro circuit is not installed, the AUT position of key

1

 is inoperable.

-

 Moving the swich towards the MAN position

 ( x 

 l 

)

(switch  no. 1) operates the delayed opening of the shutter

and the LED indicator  lights.

-

 Moving the switch

 ( 

 l 

 )

 switch no. 2 operates the

motor as an extractor 01 blower.

-

 Moving the switch

 (1, 11,

 Ill) switch no. 3 changes the Speed

of the motor.

B-23

 WITH

 HYGRO WITH

 RB 

23/30 SWITCH

DIAGRAM (C)

- 6 wires from the RB 23/30 switching unit to the connection

in the 8-23 fan unit (connection cover

 -

 Strip) (see diagram

C) in addition to two power cables for the RB 23/30 switch
and an earth connection to eliminate any interference.

-

 Move switch no. 1 

(x . 

 to the AUT position. The fan

is controlled by the degree of humidity in the premises.
When humidity is detected the fan will start Operation as an

extractor  at maximum speed, the LED indicator  will light
and the shutters open. This position cancels the operations

of switches no. 2 and no. 3. The degree of humidity detec-

ted can be adjusted by turning the blue knob. The red knob
adjusts the timer.

B-23 WITHOUT RB 23/30

 SWITCH

Connect the B-23 fan unit without the RB 23/30 switch as

shown in diagram A. Use a two-Position double switch.
B-23 (extractor  function) according to diagram no. 

1.

B-23 (blower function) according to diagram no. 0.

CERTIFICATE OF GUARANTEE

We grant 

1

 year guarantee on the product. In the event this

product fails to function properly during the guarantee

period, the product will be repaired free of Charge  unless the

said malfunction  is the result of improper use or modification.

This guarantee is in addition to any rights of the purchaser
pursuant  to regulations in forte.

CONDITIONS OF GUARANTEE VALIDITY

- No Claim will be taken into account without the guarantee

card, which must be duly completed, including the
purchase  date and the retailer’s stamp.

- Upon purchasing the equipment, insisT that the guarantee

card is duly filled in.

- All guarantee repairs must be performed by an authorized

CATA Technical Assistance Service.

-

 Front grid

-

 Shutters

-

 Cirtuit cover

-

 Connection box cover

-

 Condenser

-

 Housing

-

 Cable cover

8

 -

 Motor

-

 Fan blades

IO

 -

 Inner ring

11 

-

 Exterior grille

12 

-

 Outer ring

13 

-

 Connection piece

14 

-

 Mechanism cover

15 

-

 Thermal-switch

Отзывы: