Specifications 

 
ZOOMSTAR

 SPECIFICATIONS 

 

  Nikon Continuous Zoom Optics 4.5x to 20x 

  Maximum height 51”; minimum height 40” 

  Overall weight 23 ½ lbs. 

  Center of column to end of leg 12” 

  Height of microscope to floor 36” to 46” 

  8 ½  foot grounded power cord 

  Fused power input lamp 2.0 amp, two fuses, 2 amp 5mm x  20mm Fast Blow Fuses 

  100-120V/200-240V AC, 50/60 Hz, 100VA 

 

TRISTAR™ SPECIFICATIONS 

 

Type  

3-Step Magnification with beamsplitter 

Warranty 7 

Years 

Power Requirements 

100-120V/200-240V AC, 50/60Hz, 100VA 

Mounting System 

5-Leg Rolling Base 

 

 

Standard Optical Configurations 

 

Objective Lens (working Distance) 

300mm 

Total Magnification 

8x, 13x, & 21x 

Field of View 

8.5x=23.4mm, 13.6x=14.6mm, 21.3x=9.4mm 

Depth of Field 

8x=3.1mm, 13.6x=1.2mm, 21.3x=0.9mm 

Ocular (Eyepieces) 

16x Highpoint, with locking diopters 

Diopter Adjustment 

Independent adjustment with position locking –6/+4 

Interpupillary Range 

54mm to 80mm 

Tilt of Viewing Head 

59 degrees 

Binocular Tube Design 

Straight 

Binocular Tube Length 

160mm 

Magnification Changer Factor 

1.0x, 1.6x, 2.5x 

Vessel Delineation Filter 

Yes 

 
 

Illumination System 
 

Illumination  

Light Emitting Diodes (LED) (5000/7000 degrees Kelvin)
Green LED for blood vessel delineation. 

 

 
Photographic Capabilities 
 

Digital, Video 

Yes 

 
 

Options 

 

Teaching Tube 

Yes 

 

 

 
 
 

IMSC036-DFU • Rev. B • 10/14                           14                                         Made in the USA 

 

Содержание TRISTAR

Страница 1: ...ULIGHT COLPOSCOPE REF 906057T 906057 40TU 906140T WALLACH SURGICAL DEVICES 95 Corporate Drive Trumbull CT 06611 USA Phone 203 799 2000 Fax 203 799 2002 www wallachsurgical com EC REP IMSC036 DFU Rev B...

Страница 2: ...8 USB Video Attachment 9 Electrical 11 Replacing the Fuses 11 Maintenance 11 Warranty Information 11 Service and Repair 12 Explanation of Symbols 13 Specifications ZoomStar Specifications 14 TriStar...

Страница 3: ...E HEAD IN LOWEST POSITION TO ASSURE STABILITY DURING TRANSPORTATION The Wallach family of Star colposcopes feature zoom and multi step magnification models mounted on a center post with an easily mane...

Страница 4: ...s The control that sets the coarse height adjustment is the large knurled hand screw on the Stand System 2 Raise the Optics to the desired height and then tighten the hand screw on the stand The fine...

Страница 5: ...us knobs to bring the target into focus The fine focus knobs can be tightened or loosened to adjust travel ease by rotating them in opposite directions Do not re adjust fine focus after a clear image...

Страница 6: ...n the Save button and then choose Yes 8 Focus to get the desired image on the screen 9 To capture the image on the screen choose Capture and then Snap Shot 10 A window will open to the right of the ma...

Страница 7: ...ontrol box b The Floorstand 2 Place the Floorstand on the floor 3 Insert the tapered end of the shaft on the bottom of the center pole into the center hole of the Floorstand Attach the center pole to...

Страница 8: ...ing to the camera by aligning the red mark on the ring with the red dot on the camera lens mount Then turn the ring until a click is heard when the attachment is secured 2 Remove the black cap on the...

Страница 9: ...ttach any analog or USB camera Please note that only one side of the C Mount Adaptor can attach to the TriStar The instructions are as follows 1 Attach the mounting ring to the camera 2 Attach the ent...

Страница 10: ...PC 5 After the C Mount has been attached to the colposcope the camera needs to be oriented so that the image on the monitor is the same as that viewed through the optical head On the C mount loosen t...

Страница 11: ...umber 109645 5 Push the fuse holder back into the electronics box Maintenance PRECAUTION DO NOT IMMERSE EQUIPMENT COMPONENTS IN LIQUID UNPLUG BEFORE CLEANING DRY BEFORE USE Clean the lenses and protec...

Страница 12: ...o a working wall receptacle 2 Check for a blown fuse if fuse needs to be replaced see directions If your Colposcope with Trulight is still inoperative remove the unit from use and contact our qualifie...

Страница 13: ...rve protect and improve the quality of the environment protect human health and utilize natural resources prudently and rationally do not dispose of waste electrical or electronic equipment WEEE as un...

Страница 14: ...Configurations Objective Lens working Distance 300mm Total Magnification 8x 13x 21x Field of View 8 5x 23 4mm 13 6x 14 6mm 21 3x 9 4mm Depth of Field 8x 3 1mm 13 6x 1 2mm 21 3x 0 9mm Ocular Eyepieces...

Страница 15: ...VIRONMENT CONDITIONS Use Environmental Temperature Relative Humidity Air Pressure between 10 C and 40 C between 10 and 90 between 700 hPa and 1060 hPa Shipping and Storage Environmental Temperature Re...

Страница 16: ...scope should assure that it is used in such an environment Emissions Test Compliance Electromagnetic Enviroment Guidance RF emissions CISPR 11 Group 1 Wallach Colposcopes use RF energy only for it int...

Страница 17: ...fferential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines...

Страница 18: ...smitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the follow...

Страница 19: ...to frequency of transmitter Meters 150 kHz to 80 MHz P v d 1 5 3 80 MHz to 800 MHz P E d 1 5 3 800 MHz to 2 5 GHz P E d 1 7 0 01 0 1167 0 1167 0 2333 0 1 0 3689 0 3689 0 7379 1 1 1667 1 1667 2 3333 1...

Страница 20: ...SURGICAL DEVICES 95 Corporate Drive Trumbull CT 06611 USA Phone 203 799 2000 Fax 203 799 2002 www wallachsurgical com IMSC036 DFU Rev B 10 14 Wallach Surgical Devices...

Отзывы: