background image

G:\INSTRUCT\Sanismart Plus\Sanismart Plus Instructions.docx 9/9/2020 Page 2 

 

 

1.  DIMENSIONS, GENERAL VIEW & CONNECTIONS 

 

Dimensions: - 

 

 

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
General view & connections: -
 

Cut-away view through the cover showing the dry mounted pump motor unit & circuit board, in a separate chamber provided in 
the collection tank. Also shown is 1 X toilet pan connection, 2 X inlet connections on sides of the tank at lower level typically for 
connecting shower, bath and other lower level amenities, 1 X additional optional connection on top of tank right side typically for 
higher level discharging amenities like hand basin, sink etc.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SANISMART PLUS DIMENSIONS 

 
 
 
 
 
 
 

 

1: Pump Cover. 

WARNING 

– Pump Cover 

is not water tight. Water 
dripping on to Pump Cover 
may cause pump failure 
and hazard. 

2: Collection Tank. 
       !!! Warning !!!

 

 

Do not dump condoms, 
sanitary pads, wet wipes, 
tampons, hair, nappies, 
non-water soluble paper 
towels, cardboard, 
plastic bags, fat, oil, 
sand, stones, tar, 
cement, paint etc. 

This may cause pump 
failure, flooding & hazard. 

3: Pan Connection 

 

4: Pump 
Discharge 

 

9: PVC Swing 
Check Valve 

 

6: Shower / Bath 
Connections on 
Either side of tank 
 

5: Tank Vent 
Connection 

 

7: Additional Optional 
Inlet Connection fat top 
for WHB / Sink 

 

8: Manual Run / 
Reset Button 

 

10: PVC Isolating 
Ball Valve 

 

Содержание SANISMART PLUS

Страница 1: ...correct operation or servicing Congratulations on your purchase of Sanismart Plus wastewater package pump For this product to meet its expected lifetime please ensure it is installed by a qualified te...

Страница 2: ...k right side typically for higher level discharging amenities like hand basin sink etc SANISMART PLUS DIMENSIONS 1 Pump Cover WARNING Pump Cover is not water tight Water dripping on to Pump Cover may...

Страница 3: ...ed in the rubber sleeve Use 40 mm pipe to run the vent to a termination point in accordance with the Building and Plumbing Code Do not use an air admittance valve e g a Hunter Valve in the vent pipe 6...

Страница 4: ...er property or person due to such jam is not covered under warranty This is a BUDGET model for domestic SECONDARY use only packaged sewage waste water pump This pump is NOT intended for use as the onl...

Страница 5: ...Pumps for advice Caution Note Pump as it is not suitable for following Please contact Wallace for suitable solution Condensate water from air conditioning unit Hot and or cold water from relief valve...

Страница 6: ...Children persons with reduced physical sensory or mental capabilities or lack of experience knowledge cannot use the product unless they have been given supervision or instruction concerning use of t...

Страница 7: ...al failure or Unit jammed due to foreign material or Power failure or Any pipe or valve blockage or In grace of water moisture in the unit or any other reason in addition to ones specified above there...

Страница 8: ...ct 230V 1Ph 10A AC Mains Power Supply to Pump from Separate power point If Washing M C OR Dishwasher needs to be stopped on Alarm mode connect 230V AC OUTPUT POWER Phase P Neutral N Earth E from Water...

Страница 9: ...valve within one metre of the pump in a vertical position This check valve to be below and close to the isolating ball valve supplied with the unit 5 All pumped appliances such as washing machines an...

Страница 10: ...on and disconnection of the power supply to the pump before and whilst carrying out any servicing work on the unit Also ensure no liquid will flow into it during servicing For this product to meet its...

Страница 11: ...damage to pump or any property or person due to such malfunction is NOT COVERED UNDER WARRANTY 6 In the event of Liquid inflow in pump higher than unit s capability or Mechanical failure or Unit jamm...

Страница 12: ...venting Blockage to pump inlet Inflow rate is too high than pump can pump out Unblock and or change the pipework to the bigger ID size Check with Wallace Visually check that the tank vent pipe is clea...

Страница 13: ...nd pump Leakage from the seal gasket between the top lid and the tank Tighten the pipework connections Check and replace if required Check and replace if necessary Check the condition of the seal Repl...

Страница 14: ...collection tank 6 Hose Pipe clamp for Pan Connector 7 Rubber Pan Connector 8 Discharge Elbow pipe connected to pump 10 Pressure Switch 11 Capacitor 12 Power Cord with Plug 13 Motor only 14 Mechanical...