C23i
Maintenance Instructions
Cleaning
59
CLEANING
CAUTION
If a pressure washer is used on the ex-
posed working parts, avoid water on the
electrical parts and the engine cooling
system.
Engine Air Cleaner System
Turbine Precleaner (Enginaire™)
The engine air cleaner system includes a turbine
precleaner; a spinning fan driven by the intake
airflow separates dust from the air, giving the initial
stage of air cleaning.
Every 100 hours
check the
Turbine Precleaner
(located in the end cap of the air cleaner assem-
bly) for free movement of the internal fan. Shine
light into end cap to verify movement of fan with
engine running.
Enginaire™ VLR Air Cleaner
A remote mounted Enginaire™ air cleaner pro-
vides the air filtering function. The paper filter
element slides over an outlet tube inside the air
cleaner canister with
radial
sealing action, reduc-
ing the possibility of dust leaks due to improper
filter installation. Intake design and internal baffling
provide dust separation and automatic precleaning
action. Daily or frequent servicing of the air clean-
er
is not required.
IMPORTANT:
Use
only
Enginaire™ air filter ele-
ments for replacement (Walker P/N 5090-5 and
5090-6). Aftermarket filters may not seal properly
or filter efficiently.
Engine Air Cleaner System Components
Engine
Hose
Clamp
Safety
Filter
Hose
Clamp
Air Intake
Hose
Turbine
Precleaner
Primary Filter
Element
Enginaire™
Air Cleaner Cover
Mounting
Band
Enginaire™ VLR
Air Cleaner