Instruction & Technical Manual | 9
5.2 Reconfiguration of inlet and outlet ports
1. Port configuration as delivered: 3 inlet
options left hand side of dryer as viewed
from front.
5. Dryer with multiport manifold
removed.
4. Remove multiport manifold by means
of 4 fixing bolts.
8. Port configuration following procedure
above.
2. Remove top cover by means of 2
fixing screws
3. Dryer with top cover removed.
7. Replace top cover by means of 2 fixing
screws.
INLETS
OUTLETS
OUTLETS
INLETS
6. Rotate multiport manifold through 180º
and replace by means of 4 fixing bolts. Ensure
2 ‘0’ rings in valve block are properly seated.