5 SERVICE AND
MAINTENANCE
5.1 SERVICE
5.1.1 FLUIDS AND LUBRICANTS
1. Grease:
Use an SAE multi-purpose high temperature
grease with extreme pressure (EP)
characteristics. Also acceptable is an SAE
multi-purpose lithium based grease.
2. Blower Oil:
Use Walinga Blower oil (part# 98-13813-6)
Imperial 80W 140 GX Extra gear oil
or equivalent.
Reservoir Capacity: +1 1/4 quarts
MODEL
6614D
7614D
Front
1 liter
1 liter
Rear
2 liters
(2.1 qts.
2 liters
(2.1 qts.
3. Storing Lubricants:
Your unit can operate at top efficiency only if
clean lubricants are used. Use clean
containers to handle all lubricants. Store them
in an area protected from dust, moisture and
other contaminants.
5.1.2 GREASING
Refer to Section 5.1.1 for recommended grease.
Use the Service Record checklist provided to
keep a record of all scheduled servicing.
1. Use a hand-held grease gun for all greasing.
2. Wipe grease fitting with a clean cloth before
greasing, to avoid injecting dirt and grit.
3. Replace and repair broken fittings
immediately.
4. If fittings will not take grease, remove and
clean thoroughly. Also clean lubricant
passageway. Replace fitting if necessary.