15.Install Electro-Static Hazard warning labels on the piping at all the pick up points. 
16.Install the chain from the dust cap to the camlock couplings. 

Options 

• Customers may have different discharge options making every installation a little 
different. 
◦ Refer to the system design drawing for every single install. 
◦ Walinga offers a dust free 2 cubic yard dust bin which will be installed under the 
Airlock. 
• A customer may also order a slide gate for underneath their Secondary Separator 
requiring installation and more sealant. 
• A selection of different electrical options are available for the customers. 
◦ Nema 4 starter control panel complete with starters for both blower and airlock 
drive motors. The panel will include a relay to control the optional slide gate. 
◦ Custom panels are available. Refer to sales contract 
◦ Note: As a rule Walinga Central-Vac systems are equipped with Toshiba 3 phase 
electric motors. Please refer to the sales contract for voltage and hp requirements, 
or contact your local Walinga representative. 
◦ 

All electrical connections must be made by a certified electrician in 

accordance with local electrical codes. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Rev.09292020                       Central-Vac  Installation Manual 

"It is the responsibility of the owner/operator of facilities in which explosion 
vents are utilized to comply with the requirements of the AHJ, which is typically 
the use of National Fire Protection Association ("NFPA") Standard 68. Owners / 
operators must deploy an appropriate number and configuration of vents; 
ensure vents are installed where activation will not cause personal injury or 
unacceptable property damage; and ensure vents are not adversely affected by 
process conditions or conditions on the non-process side of the vent. Seller's 
installation and operating instructions shall be followed by the Buyer." 

 

Содержание Central Vac

Страница 1: ...INSTALLATION MANUAL Central Vac Installation Manual...

Страница 2: ......

Страница 3: ...USA 1 800 466 1197 ext 8 Email warranty usa walinga com Australia 07 4634 7344 Email mail customvac com au GUELPH SERVICE Kevin VanderZwaag 519 763 7000 ext 273 kevin vanderzwaag walinga com ORIGINAL...

Страница 4: ...preventing injury Wear the appropriate protective gear Ensure that the Central Vac is anchored to firm and level ground Make certain that sufficient amperage at the proper voltage and frequency 60Hz i...

Страница 5: ...Components of a Central Vac System 1 2 3 4 5...

Страница 6: ...Typical Central Vac Set Up...

Страница 7: ...he tank towards the airlock 55 high X 19 diameter Where gaskets are not available use silicon to seal between components in order to maintain a constant vacuum The Primary Separator is bolted onto the...

Страница 8: ...motor and chain drive and has to be placed in an easily accessible location for service 3 Secondary Receiver Separator Placed after the primary separator the secondary separator operates the same way...

Страница 9: ...needs to be mated bolted and siliconed together A full seal is required to maintain constant vacuum The secondary separator will also have two ports both 6 diameter The 6 pipe heading out of the top...

Страница 10: ...e obstructed 31 3 8 high and 25 1 2 wide The 6 port coming out of the top of the filter housing will lead towards the blower package 5 Blower Package The blower package generates the suction and press...

Страница 11: ......

Страница 12: ...unit will be equipped with a 3 mainline and 2 drop lines Galvanized steel elbows Used for corners in the piping system Available in 2 3 4 and 6 6 elbows are utilized between the blower filter housing...

Страница 13: ...ound strip is put into place in order to prevent static electricity build up Mounting Brackets The mounting brackets are mounted to the wall or to any other solid support The saddle clamps are attache...

Страница 14: ...entral vac system and is used for by the operator Has a static wire built into it to prevent static electricity build up If servicing a rubber hose ensure that the ground wire is making contact with t...

Страница 15: ...and to prevent connection leaks When installing a camlock coupling be sure to have a ring of silicone around the piping and have the coupler closed Camlocks must be installed with dust plugs inserted...

Страница 16: ...e as straight as possible to maintain maximum conveying rate Space the inlets and the inlet piping at a maximum of 40 apart Or in accordance with piping layout drawing provided When installing the inl...

Страница 17: ...components are easily accessible for any future service and maintenance Electro Static hazard warning labels must be installed on the piping by all inlets For ease in future maintenance install all t...

Страница 18: ...Typical System Design...

Страница 19: ...e filter inside the basket at the bottom of the filter cannister 9 Run the 6 piping along with the 6 elbows and 6 compression couplers from the secondary separator out of the top down to the inlet por...

Страница 20: ...fer to sales contract Note As a rule Walinga Central Vac systems are equipped with Toshiba 3 phase electric motors Please refer to the sales contract for voltage and hp requirements or contact your lo...

Отзывы: