background image

 

 

22 

02/09 

 

14.

 

Technical Specifications 

Device 

 

Power supply 

AC 220 - 230 V / 50 Hz 

Weight 

1,53 kg 

Vertical pivoting radius 

180 ° 

Dimensions incl. (HxWxD) 

18 cm x 18 cm x 32 cm 

Accessories 

Reflector, Power cord (4 m), Lamp,  

Instruction manual 

 
 

Lamp 

 

Quartz lamp 

1 x 1000W 

Colour temperature 

3200 K 

Socket 

G9,5 two pins 

Micro-fuse 

6,3 A 

Permitted operation 
temperature 

-10 °C to + 40 °C 

Storage conditions 

Dry and dust-free in carton at 

-20 °C to +50 °C 

 

Содержание VC-1000Q

Страница 1: ...Copy of Instruction Manual VC Quarzlight 1000Q...

Страница 2: ...ction cap 11 6 3 Demount and mount reflector 13 6 4 Plug in and out of lamp 13 6 5 Connect to power supply 14 7 Operation of the device 15 7 1 Adjust tilt angle 15 7 2 Switch the device on and off 15...

Страница 3: ...ource The main features of your device as follows stable light with constant colour temperature reliable cooling fan rotatable and tiltable socket which fits on every common lamp tripod very lightweig...

Страница 4: ...the local disposal points 1 2 Markings in the manual Marking Meaning Indicates the handling and consequences of safety notes WARNING Indicates a hazardous situation which if not avoided could result i...

Страница 5: ...y could overturn the device Avoid placing cables where they can be tripped over The device could be overturned WARNING Danger of electric shock burn hazard Please note that the device is still connect...

Страница 6: ...falling down In case of falling down please let an electrician check the device before switching on again If your device should be damaged or defect or if you notice a burning smell Disconnect the pow...

Страница 7: ...ose distance to the device CAUTION Danger of burning on hot parts The lamp could heat up to 400 450 C Don t touch the parts during operation and cooling down Please cool down your device completely be...

Страница 8: ...se just use lamps which comply with EN 60357 Page 3155 3 Unpack and check the device Please unpack your device carefully Please check if the delivery is complete o 1 VC 1000Q Quarzlight o 1 Reflector...

Страница 9: ...ctor B Lamp C VC Quarzlight 1000Q D Ventilation slots E Holder for tripod G Tilt lever H Unlocking lever for reflector A Tappet switch POWER O I B Output controller C Fuse holder for micro fuse D E So...

Страница 10: ...s in the respective chapters throughout operation Mount on tripod optional Demount mount protection cap Mount reflector Plug in lamp Adjust tilt angle Connect to power supply Switch on device Switch o...

Страница 11: ...lever 2 Open fixing knurl 3 Mount the device on the tripod 4 Tighten fixing knurl 5 Close locking lever 6 2 Demount and mount protection cap WARNING Danger of bursting of lamp Make sure not to touch t...

Страница 12: ...e cool down for approx 50 minutes Push back unlocking lever and keep pressed Plug in the protection cap into the three openings on the device turn it clockwise and listen for the cap to snap into plac...

Страница 13: ...onto the unlocking lever Demount reflector WARNING Danger of burning on reflector and lamp Please let the device cool down for approx 50 minutes Remove safety cap from unlocking lever Push back unloc...

Страница 14: ...e a cloth or wear gloves WARNING Danger of electric shock on all lamp sockets 10 Screw out lamp Screw out the lamp carefully and store it securely A B Lamp socket Lamp 6 5 Connect to power supply 1 Sw...

Страница 15: ...lights up 2 Switch off device Set main switch POWER on O If lamp was switched on The lamp will go out The lighting of the switch goes out 7 3 Switch lamp on and off The lamp can be switched on and off...

Страница 16: ...ning through hot parts Let the device cool down completely 3 Demount reflector See Mount and demount reflector 4 Demount power cord 5 Clean the device if necessary See Cleaning 6 Put the device and al...

Страница 17: ...ugged or plugged incorrect Plug in the power cord correctly Micro fuse is defect Change micro fuse see Change micro fuse Lamp do not light up Lamp is switched off Switch on lamp see Screw in and out o...

Страница 18: ...in firmly In case of damage WARNING Danger of electric shock and fire through short circuit The device should be repaired by an electrician immediately X 10 2 Cleaning WARNING Danger of cutting and sp...

Страница 19: ...ber cloth 10 3 Change lamp WARNING Please just use lamps which are conform with the required specifications See Technical Specifications 1 Screw lamp out and in See Screw in and out of lamp 10 4 Chang...

Страница 20: ...up the fuse holder carefully and slightly 4 Pull out the fuse holder with your hands completely out of the slot 5 Take out old micro fuse 6 Take the new micro fuse out of the spare slot and slide it...

Страница 21: ...Part of the device Item number Lamp walimex pro Spare lamp VC 1000Q 15952 Power cord 12914 Reflector 13119 Protection cap 13538 13 Disposal and environment protection Your device should be disposed f...

Страница 22: ...ius 180 Dimensions incl HxWxD 18 cm x 18 cm x 32 cm Accessories Reflector Power cord 4 m Lamp Instruction manual Lamp Quartz lamp 1 x 1000W Colour temperature 3200 K Socket G9 5 two pins Micro fuse 6...

Страница 23: ...10 08 Foto Walser GmbH Co KG Gewerbering 26 86666 Burgheim Tel 49 84 32 9489 0 Fax 49 84 32 9489 8333 eMail info foto walser de Internet www foto walser de...