22
Gas Conversion and Specifications
Gas Regulator
- NAT Gas / LPG / Butane Only.
NOTE: The gas regulator supplied is
convertible between Natural Gas
and LP Gas, but it’s outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn ‘On’ gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure operating pressure at manifold test point
with two burners operating at 'High Flame' setting.
4.
Verify operating pressure remains correct (Re-adjust regulator if required).
5.
Screw cap nut back onto regulator.
Gas Type Identification Label
1.
On completion of gas conversion, replace gas type identification label located at:-
2.
- Rear of appliance, above gas connection.
3.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning