Installation

 

Regulator connections are 

3

/

4

" BSP female. 

Connection to appliance is 

3

/

4

" BSP male. 

(Refer to ‘Specifications’ section for gas supply location dimensions). 

 

NOTE:  A Manual Isolation Valve must be fitted to individual appliance supply line. 

 

4. 

Correctly locate appliance into its final operating position and using a spirit level, adjust legs so 

appliance is level and at correct height. 

5. 

Connect gas supply to appliance.  A suitable joining compound which resists breakdown action of 

LPG must be used on every gas line connection, unless compression fittings are used. 

6. 

Check all gas connections for leakages using soapy water or other gas detecting equipment. 

7. 

Check gas operating pressure is as shown in 

‘Specifications’ section. 

 

NOTE: Operating pressure is to be measured at 

manifold test point with 2 burners 
operating at ‘High Flame’ setting. 

 

8. 

Verify operating pressure remains correct. 

 

 

 

Commissioning 

1. 

Before leaving new installation; 

a.  Check the following functions in accordance with operating instructions specified in ‘Operation’ 

section of this manual:- 



Lighting the Open Burners (F - Flame Failure Option). 



Lighting the Open Burners (PF - Pilot and Flame Failure Option). 



Check the Low Fire burner operation. 



Light the Oven Pilot and Main Burners. 



Check the Oven Main Burner Thermostat operation. 



Turning the Oven to ‘Stand-By’ Mode. 



Oven ‘Shut Down’. 

 

b.  Ensure operator has been instructed in areas of correct lighting, operation, and shutdown 

procedure for appliance. 

 

2. 

This manual must be kept by owner for future reference, and a record of 

Date of Purchase, Date 

of Installation and Serial Number of Appliance recorded and kept with this manual. (These 

details can be found on Rating Plate attached to bottom right hand corner of bottom sill.  
Refer to ‘Gas Connection’ section)

 

NOTE: If for some reason it is not possible to get appliance to operate correctly, shut off gas 

supply and contact supplier of this appliance. 

Manifold 

Test Point 

Fig 2 

 
 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Warning 

Содержание RN8910G

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Series RN8910G RNL8910G RNB8910G RNLB8910G Gas Range Static Oven Date Purchased Serial Number Dealer Service Provider 232779 8 For use in GB IE ...

Страница 2: ...pares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales ...

Страница 3: ...Location Clearances Assembly Gas Connection Commissioning Operation 10 Operation Guide Description of Controls Open Burners Lighting the Oven Pilot Burner Lighting the Oven Main Burner Turning the Oven to Stand By Pilot ON Only Oven Shut Down Cleaning and Maintenance 14 Before Commencing Cleaning Open Burner Cleaning Oven Interior Cleaning Stainless Steel Surfaces Fault Finding 16 Gas Conversion a...

Страница 4: ...PPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This a...

Страница 5: ...Pilot and Flame Failure Protection General A heavy duty general purpose gas range created for compact modular kitchens It is available on industrial adjustable feet or on robust rollers Open Burners are available in either PF Pilot and Flame Failure or F Flame Failure Only options Open Burners are fitted with individual flame failure for each open burner Oven is fitted with pilot and flame failure...

Страница 6: ...minal 6 5 kW 7 8 kW 6 5 kW 7 8 kW Reduced 1 75 kW 1 75 kW Gas Rate nett Nominal 0 69 m3 hr 0 83 m3 hr 0 51 kg hr 0 61 kg hr Reduced 0 19 m3 hr 0 14 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 5 mbar 26 mbar Gas Connection 3 4 B S P Male Natural Gas LP Gas Propane Input Rate N H G C each Open Burner 28 MJ hr 28 MJ hr Oven 30 MJ hr 30 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 ...

Страница 7: ...proximately 130mm from right hand side 32mm from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions section Connection is BSP male thread Electrical Supply Requirements 230 240 V a c 50 Hz 1 6A 1P N E 0 4kW Oven Fan Motor 100W Natural Gas Town Gas Input Rate N H G C each Open Burner 28MJ hr 28MJ hr Oven 30 MJ hr 30 MJ hr Supply Pressure 1 13 3 40kPa 0 75 1 50kPa Bu...

Страница 8: ...6 Dimensions RN L 8910G ...

Страница 9: ...y the manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to dis...

Страница 10: ... the appliance has been supplied for is shown on coloured stickers located above gas connection point and on rating plate Check this is correct for gas supply appliance is being installed for Gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supply pressure exists c...

Страница 11: ...mmissioning 1 Before leaving new installation a Check the following functions in accordance with operating instructions specified in Operation section of this manual Lighting the Open Burners F Flame Failure Option Lighting the Open Burners PF Pilot and Flame Failure Option Check the Low Fire burner operation Light the Oven Pilot and Main Burners Check the Oven Main Burner Thermostat operation Tur...

Страница 12: ...tion Oven Pilot Ignition Oven Main Burner Thermostat Turning the Oven to Stand By Mode Oven Shut Down Description of Controls Piezo Igniter Oven Oven Option OFF Position PILOT Burner Temperature Graduations 100 C to 290 C Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators are located above the Gas Control Knobs Fig 3 This appliance is for professional use and ...

Страница 13: ...nually re light burner each time that it is turned ON as burner will automatically light itself off the pilot burner Flame Failure Protection is incorporated for each burner by way of a thermo electric system which will shut off gas supply to that burner in the event that burner goes out so that un burnt gas is not expelled a Select burner required depress and turn the gas control knob anti clockw...

Страница 14: ...f pilot does not light repeat Items 1 to 3 above 4 View oven pilot burner through holes in front of sole plate with oven door open Lighting the Oven Main Burner 1 Ensure pilot burner is alight 2 Rotate thermostat control knob anti clockwise to desired temperature marked on knob 3 Main burner will ignite automatically from pilot burner Turning the Oven to Stand by Pilot ON Only NOTE DO NOT attempt ...

Страница 15: ...O NOT fully depress Thermostat Control Knob whilst trying to rotate clockwise to O Off position as Knob and Gas Valve will be damaged Control Knob in Off Position Partially Depress and Rotate Knob to the O Off Position IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control problems partial or full loss of burner flame in normal operation appliance requi...

Страница 16: ...ng material has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas supply before cleaning the appliance This appliance is not water proof Do not use water jet spray to clean interior or exterior of this appliance Caution Burner Body Spill Tray Pot Stand Burner Cap Burner Mounting Rail ...

Страница 17: ...mpty spill tray and wash with warm soapy water 5 Dry all components thoroughly and re assemble Oven Interior Cleaning 1 Do not use wire brushes steel wool or other abrasive materials to clean oven interior 2 Clean oven regularly with a good quality domestic oven cleaner 3 Weekly Remove and clean any built up of grease etc from oven racks and bottom spill cover 4 Dry oven thoroughly with a dry clot...

Страница 18: ...d Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tighten thermocouple connection Check thermo cou...

Страница 19: ...ands burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot stand supports pot stands burner caps and burner bodies 4 Re light main burners and check flame size on simmer LOW position Adjust low fire adjustment screw on open burner gas control valves to obtain d...

Страница 20: ...orrect size injectors as shown in Gas Specifications Tables at end of this section 4 Refit the following Re connect pilot supply tube to pilot burner Re connect piezo igniter and thermocouple to mounting bracket Refit main burner and sole plate s 5 To Replace the low fire screw in the gas valve Remove the oven control panel Remove low fire screw from gas valve and replace with correct size low fir...

Страница 21: ... Re adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Identification Label On completion of gas conversion replace gas type identification label located at Rear of appliance above gas connection Beside the rating plate Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commis...

Страница 22: ... Setting Fully Open Fully Open Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas LP Gas Open Burner Main Burner Injectors Ø 2 45mm Ø 1 50mm Pilot Burner PF Option Only 0 30 0 20 Oven Main Burner Ø 2 60mm Ø 1 60mm Pilot Burner 0 35 0 23 Burner Aeration Setting Fully Open Fully Open Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa B...

Страница 23: ...ner Main Burner Ø 2 45mm Ø 4 50mm Pilot Burner PF Option Only 0 30 0 60 Oven Main Burner Ø 2 6mm Ø 5 0mm Pilot Burner 0 35 0 60 Low Fire Ø 1 5mm Ø 2 50mm Burner Aeration Setting Fully Open Fully Open Supply Pressure 1 13 3 4 kPa 0 75 1 50 kPa Burner Operating Pressure 0 95 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to Burner Operating Pressure specified LP Gas Propane Butane ...

Страница 24: ... Nat Gas 0 30 026136 Pilot Injector LP Gas Butane 0 20 232309 Pilot Injector Town Gas 0 60 229442 Pilot Bracket Assembly 229444 Pilot Burner Shield 227405 Gas Control Valve with Flame Failure 227403 Gas Control Valve with Pilot Flame Failure 227967 Knob Open Burner with Flame Failure 227384 Knob Open Burner with Pilot Flame Failure 228167 Thermocouple 320mm Front 228166 Thermocouple 600mm Rear IMP...

Страница 25: ...zo Ignitor 018744 Electrode 019407 H T Lead 228704 Door Spring Kit Includes 2 Springs 227386 Knob Oven 100 290 C 227893 Oven Side Rack RH 227892 Oven Side Rack LH 227896 Oven Rack General 232535 Pot Stand 228883 Spill Tray 450mm 229674 Rear Roller Assy 227850 Adjustable Leg 150mm Accessories 228800 900mm Plinth Kit Gas Regulators Gas Conversion Kits NOTE Each gas conversion kit is universal for al...

Страница 26: ......

Отзывы: