4
Specifications
Gas Supply Requirements
- Non - CE Only:
- CE Only
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
(
*
) Burner operating pressure is to be measured at manifold test point with two burners operating
at full setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’
section for details).
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal
6.5 kW
5.5 kW
8.0 kW
6.5 kW
5.5 kW
8.0 kW
Reduced
1.75 kW
1.85 kW
2.4 kW
1.75 kW
1.95 kW
2.4 kW
Gas Rate
(nett)
Nominal
0.69 m
3
/hr
0.58 m
3
/hr
0.85 m
3
/hr
0.51 kg/hr
0.43 kg/hr
0.62 kg/hr
Reduced
0.19 m
3
/hr
0.20 m
3
/hr
0.25 m
3
/hr
0.14 kg/hr
0.15 kg/hr
0.19 kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar
26 mbar
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
- each 300 mm Griddle Section
21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
- Oven
30 MJ/hr
(28,434 Btu/hr)
30 MJ/hr
(28,434 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
Burner Operating Pressure
0.95 kPa (*)
(3.7” w.c.)
2.6 kPa (*)
(10” w.c.)
Gas Connection
3
/
4
” B.S.P. Male
Содержание RN8610G
Страница 7: ...5 Dimensions RN L 8510G Cook Top Options RN L 8510G RN L 8513G...
Страница 8: ...6 Dimensions RN L 8610G Cook Top Options RN L 8610G RN L 8613G RN L 8616G RN L 8619G...
Страница 9: ...7 Dimensions RN L 8810G Cook Top Options RN L 8810G RN L 8813G RN L 8816G RN L 8819G...
Страница 28: ......