Specifications
Electrical Supply Requirements
Electrical Connection
On
Leg Stand, Cabinet Base and Refrigeration Base Models
, the electrical supply connection
point is located at the rear of the appliance, approximately 130 mm from the right hand side and 32
mm from the rear of the appliance and 710 mm from the floor.
On
RN8200E Bench Models
the connection point is located approx 100 mm from the right hand
side, 110 mm from bench height and 32 mm from the rear.
On
RN8400E and RN8600E Bench Models
the connection point is located approx 130 mm from
the right hand side, 110 mm from bench height and 32 mm from the rear. (Refer to the
‘Dimensions’ section).
When connecting a this electric appliance to the mains supply, ensure that the following is carried
out:-
•
An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
•
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
•
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
•
A grommet is fitted around the wiring entry hole into the appliance.
•
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
WARNING:
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
For the Refrigeration Cabinet Specifications, refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Model
Power Supply
Total Power
Input
Amps
Voltage
Type
Frequency
L1
L2
L3
RN8200E
230-240 Vac
1 P+N+E
50 / 60 Hz
4.8 kW
20.0
---
---
RN8203E
230-240 Vac
1 P+N+E
50 / 60 Hz
3.4 kW
14.2
---
---
RN8400E
400-415 Vac
2 P+N+E
50 / 60 Hz
9.6 kW
20.0
20.0
---
RN8403E
400-415 Vac
2 P+N+E
50 / 60 Hz
8.2 kW
14.2
20.0
---
RN8406E
400-415 Vac
2 P+N+E
50 / 60 Hz
6.8 kW
14.2
14.2
---
RN8600E
400-415 Vac
3 P+N+E
50 / 60 Hz
14.4 kW
20.0
20.0
20.0
RN8603E
400-415 Vac
3 P+N+E
50 / 60 Hz
13.2 kW
20.0
20.0
20.0
RN8606E
400-415 Vac
3 P+N+E
50 / 60 Hz
11.6 kW
14.2
14.2
20.0
RN8609E
400-415 Vac
3 P+N+E
50 / 60 Hz
10.2 kW
14.2
14.2
14.2