20
Gas Conversion and Specifications
Conversion Procedure
NOTE:
These conversions should only be carried out by qualified persons. All connections must
be checked for leaks before re-commissioning appliance.
Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) can
only be adjusted in accordance with following instructions and shell be re-sealed before re
-commissioning this appliance.
For all relevant gas specifications refer to ‘Gas Specifications’ table at end of this section.
Main Burners
1.
Remove the following:-
Gas control knobs.
Control Panel.
Disconnect electrical connection lead from rear of piezo
igniters.
2.
Remove main burner injectors and replace with correct size
injectors as shown in ‘Gas Specifications Tables’ at rear of
this section.
Pilot Burners
1.
Carry out the following:-
Lead to piezo igniter.
Unscrew and remove piezo igniter.
Slacken gas supply tube at gas control end.
Disconnect gas supply tube to pilot burner.
2.
Remove pilot injectors and replace with correct size injectors as
shown in ‘Gas Specifications Tables’ at rear of this section.
3.
Reconnect the following:-
Gas supply tube to pilot burner.
Tighten gas supply tube at gas control end.
Refit piezo igniter.
Re-connect lead to piezo igniter.
Low Fire Adjustment - (Gas Griddle)
To change gas griddle thermostat ‘Low Fire’ adjustment, low fire screw on
gas control valve should be screwed fully in, then un-screwed by 1 full
turn as shown in ‘Gas Specifications’ table at end of this section.
1.
Screw ‘Low Fire’ screw fully ‘IN’ and then unscrew by
1 Full Turn
of ‘Low Fire’ screw. (Refer to ‘Gas Specification’ table at rear of this
section).
2.
Ensure Gas Control Pilot Screw is adjusted to 3 turns out c.c.w.
3. Refit
control
panel
4.
Refit gas control knob.
NOTE: ‘Low Fire Screw’ should be sealed with coloured paint on completion of low fire adjustment.
Main Injector
Piezo
Igniter
Pilot Injector Gas
Supply Pipe
Thermocouple
Thermocouple
Pilot Injector
Piezo Igniter
Viewed from inside Burner Box
Ensure Appliance is isolated from gas supply before commencing servicing.
Caution
Low Fire
Adjust Screw
Pilot Screw