22
Fault Finding
Fault Finding the Electrical System
Fault
Possible Cause
Remedy
Elements do not Heat Up.
Check mains power is supplied to the unit
and that a circuit breaker or fuse has not
tripped / blown.
Check element is flat and that the tilt
microswitch is closed.
Check thermostat setting is correct and
that control knob is set to 'ON' position.
Turn ‘On’ power. Reset circuit breaker or
replace blown fuse.
Adjust microswitch so that the microswitch
is activated when element is fully down in
the flat (cooking position).
Replace the thermostat.
Call service provider.
Over-Temperature Thermostat Cuts
Out.
Over-temperature thermostat faulty.
Control thermostat not maintaining set
temperature.
a. Thermostat out of calibration.
b. Thermostat does not open on
temperature rise.
Thermostat opens on temperature rise but
electrical contactor does not respond.
If overtemp cuts out below 220ºC, replace
over-temperature thermostat.
Call service provider.
Check continuity through thermostat leads,
on temperature rise. If circuit does not
open, replace the thermostat.
Call service provider.
Check electrical connections are correct.
Call service provider.