28
Manual switching
ENG
5. Manual switching
The
LTS/ST
device is used to switch one
luminaire.
X
Tap the button
B
The luminaire switches to the next
switching state.
The possible switching states depend on
the mode set in the device and the lumi-
naire model, see Tab. 5.
The device can be configured individually.
5.1 Factory setting
In the factory setting, the LTS/ST device is
set to mode 4, see Tab. 5.
5.2 Setting the mode
Mode
Luminaire model (key)
Switching states
1
MS
Switching dimming stages
100% / 90% / 80% / 70% /
60% / 50% / 40% / off
2
MS
40% / off
RGB
green / yellow
3
MS
70% / off
RGB
red / yellow
4
S, MS
100% / off
RGB
yellow / off
Mode
Luminaire model (key)
Switching states
5
MS
100% / 70%
RGB
red / off
6
MS
100% / 40%
RGB
green / off
7
RGB
red / yellow / green / off
Tab. 5: LTS/ST modes.
X
Tap and hold button
B
for 10 seconds,
see Fig. 1.
The connected luminaire flashes three
times.
The settings menu is active.
X
To set the desired mode, tap the but-
ton
B
as many times as the mode num-
ber.
The connected luminaire flashes once
each time the button is pressed.
X
If you have reached the desired mode:
Wait for 10 seconds.
The connected luminaire flashes as
many times as the number of the set
mode.
The settings menu is exited.