TM

4) Screen of  “HOME” and

 

 “FILE system” 

Fig. 17

Introduction of 
EndoPro 
Smart-Touch

Brightness 

File brand

File name

Calibration

Back to
 factory setting

a:

  "           "

b:

  "         "

Fig.17

4.4 Operation Instructions

1) Turn on the main unit, the screen shows the file system or parameters last time automatically.With memory

 function. The instrument will automatically shut down after 4 minutes without operation.

2) Click the menu bar at the top of the screen to enter each interface to select operations.

3)Click "Program ", for entering user-defined parameters settings. Click the blue button  "       " to self-define and 

store 9 programs, click the "    "and "    "keys to change the setting and parameters, and click "        " to select 

4 file working modes. If the "Apex " icon is "       " it means the instrument enters root canal enlargement 

function; and when the "Apex " icon is "      " it means both length-measurement and enlargement.

   When using the function of the combination of ENDO enlargement with apex locator, the motor speed will decelerate 

      

automatically and faster beeps would be heard when near the apical zone, the motor will 

automatically set in the auto reverse mode.

A Speed setting: Speed is from 150rpm to 1000rpm

B Torque setting: Torque is from 0.6N.cm to 4.6N.cm

       Notice: If use the function of combination ENDO enlargement with apex locator, the 
contra-angle must be covered by the rubber case.

4

Click "      " to select different built-in file systems. After selecting the corresponding brand file,

 click "     " to select 4 different file working modes. If the "Apex" icon is "      "

it means the 

instrument enters root canal enlargement function; and when the "Apex"  icon is "     "

it means

 both length-measurement and enlargement.

5)Insert the single head measuring wire plug into the measuring hole at the bottom of the handle, 

insert the lip hook into the hole of the single head measuring wire, and insert the endodontic file 

into the contra angle head. (Fig 18)

13

off

off

Insert into single 
head measuring line hole

Insert the handle 
into the tail line hole

7) Click the "        " button in the lower right corner of the screen, and then click  "       " to adjust 

the screen brightness;

8) Click the "         " button in the lower right corner of the screen, and then click "          " to enter 

Fig.18

Fig.19

14

6) Turn the apex mode on and press the handIe button to make the motor 

work. Use the bending head of the lip hook on the single head measuring wire to contact the 

metal shaft of the part of the file (Fig. 18). The screen should display ’--" and reach the apical  

area, accompanied by a quick beep. This means it can both measure root canal length and 

also enlarge the canal in this mode. (Fig.19)

Содержание ENDO PRO SMART-TOUCH

Страница 1: ...ENDO PRO SMART TOUCH USER MANUAL W A L D E N T TM...

Страница 2: ...ting the Main unit and Handpiec 3 2 Connecting the Main unit and Handpiece 6 3 3 Connecting the Main unit and Components 7 3 4 Automatic shutdown 7 4 Equipment instructions 7 4 1 Instructions for root...

Страница 3: ...e and pressure to avoid cross infection 1 2 Model Dimensions and Weight of the main unit Model EndoPro Smart Touch 1 3 Structure EndoPro Smart Touch is composed of main unit motor handpiece contra ang...

Страница 4: ...1 Product appearance structure ON OFF Button Screen Charging Indicator Charging Port Handpiece port Measuring Port Battery cover 2 The figures of the main accessories Fig 2 i Adapter Fig 2 The figure...

Страница 5: ...oper operation of the device 2 5 This device has electromagnetic interference which is similar to other devices patients or doctors with pacemakers are forbidden to use this device 2 6 While being in...

Страница 6: ...Press the ON OFF button turn it on 2 Click the Apex on the screen 3 click the sound button icon on the right side of the After entering the root canal length mode screen to turn on off the tip positio...

Страница 7: ...s less than 2mm Corner of mouth Lip hook File clip push File handle Metallic part of file Working and moving part of file Do not clamp on this part fig 12 a b c 9 10 When the file reaches the apical p...

Страница 8: ...y sign 3 Screen of Recipro and other functions Fig 16 Fig 16 2 Screen of Rotary Fig 15 File Brand Files name Color of files Speed Working mode Change File sizes Torque 11 12 PREMIUM TAPER W A L D E N...

Страница 9: ...150rpm to 1000rpm B Torque setting Torque is from 0 6N cm to 4 6N cm Notice If use the function of combination ENDO enlargement with apex locator the contra angle must be covered by the rubber case 4...

Страница 10: ...ot canal in a bad Situation 2 Electromagnetic interference 1 Removal of liquid and residual pulp 2 Please check the equipment used nearby and be away from interference Endo file does not reverse rotat...

Страница 11: ...ber Attention consult accompanying document Class II equipment Type B applied part Direct current Ordinary equipment 10 Statement All rights of modifying the product are reserved with the manufacturer...

Отзывы: