WALFLEX GOLD
PREMIUM TAPER
WALFLEX GLIDE PATH
RETREATMENT FILE
WAL-FLEX ONE
REC
W A L D E N T
TM
4) Screen of “HOME” and
“FILE system”
(
Fig. 17
)
Introduction of
EndoPro
Smart-Touch
Brightness
File brand
File name
Calibration
Back to
factory setting
a:
" "
b:
" "
Fig.17
4.4 Operation Instructions
1) Turn on the main unit, the screen shows the file system or parameters last time automatically.With memory
function. The instrument will automatically shut down after 4 minutes without operation.
2) Click the menu bar at the top of the screen to enter each interface to select operations.
3)Click "Program ", for entering user-defined parameters settings. Click the blue button " " to self-define and
store 9 programs, click the " "and " "keys to change the setting and parameters, and click " " to select
4 file working modes. If the "Apex " icon is " " it means the instrument enters root canal enlargement
function; and when the "Apex " icon is " " it means both length-measurement and enlargement.
When using the function of the combination of ENDO enlargement with apex locator, the motor speed will decelerate
automatically and faster beeps would be heard when near the apical zone, the motor will
automatically set in the auto reverse mode.
A Speed setting: Speed is from 150rpm to 1000rpm
B Torque setting: Torque is from 0.6N.cm to 4.6N.cm
Notice: If use the function of combination ENDO enlargement with apex locator, the
contra-angle must be covered by the rubber case.
4
)
Click " " to select different built-in file systems. After selecting the corresponding brand file,
click " " to select 4 different file working modes. If the "Apex" icon is " "
,
it means the
instrument enters root canal enlargement function; and when the "Apex" icon is " "
,
it means
both length-measurement and enlargement.
5)Insert the single head measuring wire plug into the measuring hole at the bottom of the handle,
insert the lip hook into the hole of the single head measuring wire, and insert the endodontic file
into the contra angle head. (Fig 18)
13
off
off
Insert into single
head measuring line hole
Insert the handle
into the tail line hole
7) Click the " " button in the lower right corner of the screen, and then click " " to adjust
the screen brightness;
8) Click the " " button in the lower right corner of the screen, and then click " " to enter
Fig.18
Fig.19
14
6) Turn the apex mode on and press the handIe button to make the motor
work. Use the bending head of the lip hook on the single head measuring wire to contact the
metal shaft of the part of the file (Fig. 18). The screen should display ’--" and reach the apical
area, accompanied by a quick beep. This means it can both measure root canal length and
also enlarge the canal in this mode. (Fig.19)