background image

356.805.003 

24

 

Date: 2019-04-04 

Appendix 2 – Power Connectors

 

 

 

 

Содержание TrackRunner Upright

Страница 1: ...WWW WAHLBERG DK AXEL GRUHNS VEJ 3 TELEPHONE 45 86 18 14 20 8270 H JBJERG EMAIL sales wahlberg dk DENMARK TrackRunner Upright Item No 356 User Manual...

Страница 2: ...rts PROTECTION FROM INJURY Fasten the product securely to a fixed surface rig or structure as described in this manual Ensure that any supporting hardware can hold at least 10 times the weight of all...

Страница 3: ...CK 11 MOUNTING THE LOAD 12 DATA LINK 13 RADIO CONTROL 13 TIPS FOR RELIABLE RADIO TRANSMISSION 14 TIPS FOR RELIABLE DATA TRANSMISSION 14 CONNECTING THE DATA LINK 14 CHANGING TRANSMITTER STATION 15 SELE...

Страница 4: ...Neutrik powerCON TRUE1 NAC3FX W TOP Power outlet Neutrik powerCON TRUE1 NAC3MX W TOP Power through capacity 13 A DMX control signal DMX 512 6 channels used DMX connection 5 pole XLR male female Wirele...

Страница 5: ...356 805 003 5 Date 2019 04 04 Drawing TrackRunner Upright 356 More detailed drawings can be found in Appendix 1 on page 23...

Страница 6: ...unting bracket power and DMX outlets it is easy to attach any DMX unit you would like to control from the moving element It runs on the same track as our regular Track Runners When the track is mounte...

Страница 7: ...operating or servicing the product Before applying power Check the Wahlberg Motion Design website at www wahlberg dk for the most recent documentation and technical information about the product Wahlb...

Страница 8: ...d that the installation respects all locally applicable regulations As a common rule a track shall always be secured with minimum one clamp at each track joint and where the track ends including each...

Страница 9: ...1 Secure the brackets C on the first track A1 from the bottom and secure it firmly to the structure truss or pipe STEP 2 Secure the brackets C on the second track A2 from the bottom and secure it just...

Страница 10: ...In the EU the cables must be HAR approved or equivalent and in the USA minimum hard usage type SJT or equivalent If you install a power plug on the power cable install a grounding type earthed plug th...

Страница 11: ...to select mode 2 for mounting from the top of the track or mode 4 for mounting from the bottom Make sure to pull out both knops C and slide the crimp on the wire into the slot D in order to secure the...

Страница 12: ...unting bracket make sure to minimize the slack in order to avoid collision with the motor gear and the tooth rack behind the bracket Using heavy loads may force the unit to shut down if the deaccelera...

Страница 13: ...n in CRMX wireless DMX to control the operation and the radio device uses the 2 4 GHz band as accepted in Europe and USA For other locations and national restrictions consult your national authority F...

Страница 14: ...r is used terminate each branch of the link Connecting the data link To connect the Track Runner Upright to data 1 Connect the DMX data output from the DMX controller to the Wireless DMX transmitter m...

Страница 15: ...ter is in transmitter mode and the TrackRunner Upright is in receiver mode If needed follow this instruction to re initialize the correct operation mode of the receiver and transmitters 1 Press the LI...

Страница 16: ...nections pointing up as for installation without DMX applied 5 Manual up fast 6 None Track Runner is stopped 7 DMX slow position ramp For normal operation of the unit and the slow medium or fast ramps...

Страница 17: ...is put back at 0 Note that it should be moved gradually towards 0 to give the motor time to slow down The lowest position should be set with channel 4 before the highest position is set with channel 5...

Страница 18: ...nd the soft limit low and high positions have been saved Finally the position control with channel 1 and 2 is now relative to the low and high position adjusted It is recommended to set the soft limit...

Страница 19: ...et above zero and therefore this channel works as a main brake Duty cycle When the unit is continually operated for more than 30 minutes at full load speed and high ambient temperatures the below duty...

Страница 20: ...he units will tend to follow that fade When fading the positions 1 The speed channel should be a set to 100 to gain the highest possible speed 2 The position channel should be added as a 16 bit channe...

Страница 21: ...ntenance can be provided by the Wahlberg Motion Design giving owners access to Wahlberg Motion Design s expertise and product knowledge in a partnership that will ensure the highest level of performan...

Страница 22: ...ear and tear Through improper use and the excessive use of force the encoding lugs and guide slots in the connector system can become so severely worn or damaged that it is possible to insert the cabl...

Страница 23: ...356 805 003 23 Date 2019 04 04 Appendix 1 Dimensions TrackRunner Upright...

Страница 24: ...356 805 003 24 Date 2019 04 04 Appendix 2 Power Connectors...

Страница 25: ...356 805 003 25 Date 2019 04 04...

Страница 26: ...r out powerCON TRUE 1 Power in 100 240 VAC powerCON TRUE 1 DMX signal out XLR 5 pole Control input DMX signal Microcontroller Motor controller Power supply DMX signal in XLR 5 pole 2 4GHz Band DMX Wir...

Страница 27: ...356 805 003 27 Date 2019 04 04 This page is intentionally left blank...

Страница 28: ...down 8 Stop the unit pull channel 4 to 0 when the desired LOW position is reached 9 Pull channel 5 to 20 the unit starts moving up 10 Stop the unit pull channel 5 to 0 when the desired HIGH position...

Отзывы: