12
13
EN
EN
Mounting Instructions
Mounting Instructions
Marey Electric Tankless Water Heater by Wahlbach
Marey Electric Tankless Water Heater by Wahlbach
3.
3�
a� Seal
b� Filter mat
c� Cold water-connection (inlet)
d� Hot water-connection (outlet)
e� Rating plate cover
b
c
e
a
d
4a.
Power supply 110-120V
4a�
Rated voltage 120V
Power Supply
L N
Inlet
Outlet
4b.
Power supply 208-240V
4b�
Rated voltage 240V
Power Supply
L1 L2
Inlet
Outlet
The appliance must be earthed properly!
The filter mat contained in accessory bag must be installed when connecting
with inlet(cold) water pipe or hose!
Ground fault circuit interrupter must be installed with the appliance, please take
page 14 for the selection of interrupter.
Please verify the voltage of power supply before installation!
Drawing A / B - Installation as under/over -sink model
The device must be installed as shown in the installation drawing on the
page.10 to 12 of this manual.
1. Mount the bracket on the wall and fix using two screws in the accessory bag,
the bracket should be upward(undersink) / downward(oversink).
2. Place the appliance on the wall bracket and snap it into position. The outlets
of appliance should be upward(undersink) / downward(oversink).
3. Tap connection: Cold water inlet (blue) and hot water outlet (red) are marked
on the rating plate (under the rating plate cover). Connect the appropriate
pipe or hose of the sanitary tap with the red-marked hot water outlet.
4. Connect power cable L, N and GROUNDING (120V models) to the power
supply (
4a
), or connect power cable L1, L2 and GROUNDING (240V models)
to the power supply (
4b
), then switch on the circuit breaker.