Common Services
Table 239: Analog Output Point (68
hex
) – Common service
Service
code
Service available
Service name
Description
Class Instance
0E
hex
Yes
Yes
Get_Attribute_Single Supplies contents of the appropriate
attribute
10
hex
No
Yes
Set_Attribute_Single Modifies an attribute value
11.3.5.26 Analog Output Point Extended 1 (6C
hex
)
The extension of the “Analog Output Point” class enables the exchange of data
from a fieldbus node that contains over 255 analog output points (AOPs). The
instance scope of the “Discrete Output Point Extended 1” class covers AOPs
from 256 to 510 in the fieldbus node.
Instance 0 (Class Attributes)
Table 240: Analog Output Point Extended 1 (6C
hex
) – Class
Attribute ID Access Name
Data type Description
Default
value
1
Get
Revision
UINT
Revision of this object
1 (0x0001)
2
Get
Max Instance
UINT
Max. number of instances
-
Instance 256 ... 510 (Analog output value 256 up to 510)
Table 241: Analog Output Point Extended 1 (6C
hex
) – Instance 256...510
Attribute ID Access Name
Data type Description
Default
value
1
Get
AopObj_Value ARRAY of
BYTE
Analog Output
-
2
Get
AopObj_Value_
Length
USINT
Length of the output data
AopObj_Value (in byte)
-
Common Services
Table 242: Analog Output Point Extended 1 (6C
hex
) – Common service
Service
code
Service available
Service name
Description
Class Instance
0E
hex
Yes
Yes
Get_Attribute_Single Supplies contents of the appropriate
attribute
10
hex
No
Yes
Set_Attribute_Single Modifies an attribute value
11.3.5.27 Analog Output Point Extended 2 (70
hex
)
The extension of the “Analog Output Point” class enables the exchange of data
from a fieldbus node that contains over 510 analog output points (AOPs). The
instance scope of the “Discrete Output Point Extended 2” class covers AOPs
from 511 to 765 in the fieldbus node.