765-4501/0100-0000
Commissioning
114
Product manual | Version: 1.1.0
8PORT IOL-A FLD EI DC 24V 2.0A
The following table lists port-specific configuration parameters.
Table 72: Port-Specific Configuration Parameters
Node Name
Node Class
Access Default Description
OverCurrentPin1, Over-
CurrentPin2, OverCur-
rentPin4
Variable
Read
0
Warning level for current upper limit on pin 1, pin
2 or pin 4; unit: 1 mA
0: monitoring not enabled
UnderCurrentPin1, Un-
derCurrentPin2, Under-
CurrentPin4
Variable
Read
0
Warning level for current lower limit on pin 1, pin
2 or pin 4; unit: 1 mA
0: monitoring not enabled
10.3.4.1.3 Reading Process Data
The OPC UA server provides nodes with process data. For example, the OPC UA client
can read out the value on pin 2 of a port in the
Pin2ProcessData
node. The path to this
node is:
Root > Object > DeviceSet > [device name] > IOLinkMaster > PortXX
> ProcessData
Note
OPC UA client can only read process output data
The process output data is written by the EtherNet/IP scanner. The OPC UA client can
only read process output data.
The following table lists port-specific process data.
Table 73: Port-Specific Process Data
Node Name
Node Class
Access
Description
Pin2ProcessData
Variable
Read
Process data on pin 2
Pin4ProcessData
Variable
Read
Process data on pin 4
10.3.4.1.4 Reading out Measured Values
The OPC UA server provides nodes with calculated measured values. For example, the
OPC UA client can read out the calculated total current of supply cable 1 in the
SumCur-
rentL
node. The path to this node is:
Root > Object > DeviceSet > [device name] > IOLinkMaster > Diag-
nostics > Current
The following table lists device-specific (calculated) measured values.
Table 74: Device-Specific (Calculated) Measured Values
Node Name
Node Class
Access
Description
SumCurrentL
Variable
Read
Total current in supply cable 1 calculated
from individual measurements; unit: mA
SumCurrentL2
Variable
Read
Total current in supply cable 2 calculated
from individual measurements; unit: mA
MeanTemperature
Variable
Read
Average value for the temperature of the
assembly, calculated from the temperature
values measured individually on the three
chips; unit: °C