Touch Panel Marine Line
Commissioning 107
762-6xxx/8000-000x TP 600
Manual
Version 1.1.0
</dg_
8.6.16 “Configuration of Serial Interface RS232” Page
The settings for the serial interface are shown on the “Configuration of Serial
Interface RS232” page.
8.6.16.1 “Serial Interface Assigned to” Group
The application that the serial interface is currently assigned to is displayed.
8.6.16.2 “Assign Owner of Serial Interface (Active after Next Controller
Reboot)” Group
You can specify the application that the serial interface is assigned to after the
next controller reboot.
Table 71: WBM “Configuration of Serial Interface RS232” Page – “Assign Owner of Serial Interface”
Group
Parameters
Explanation
Linux
®
Console
Specify that the serial interface is assigned to the
Linux
®
console.
Unassigned (usage by
applications, libraries,
CODESYS)
Specify that the serial interface is not to be assigned
to any particular application and is available, so that
the CODESYS program, for example, can access it
via function blocks.
Remove RS-485 devices before switching to “Linux Console”!
Connected RS-485 devices can be damaged when switching to “Linux Console”.
Remove these devices before switching!
Click
[Change Owner]
to apply the change. The change only takes effect after
restarting the controller. For this purpose, use the WBM reboot function. Do not
shut down the controller too early!