Compact Power
Connect Devices 43
787-1211 DC power supply, 12 V
Manual
Version 1.
1
.0
5.1.1
Connecting Conductors
WAGO's connectors are designed for solid or fine-stranded wires with and
without ferrules.
Connect only one conductor per connector!
You must only connect one conductor to each spring clamp connection. Do not
connect more than one conductor at a single connection!
5.1.1.1 Connecting Using a Tool
You have to use a screwdriver or an operating tool to connect the following
conductors:
•
Fine-stranded conductors without ferrules
•
Fine-stranded conductors with uninsulated ferrule, cross section
≤
0.5 mm²/AWG 22
Proceed as follows:
1.
To open the spring clamp, depress the orange push-button with a tool.
2.
Insert the conductor into the corresponding connection opening.
3.
To close the spring clamp connection, release the push-button. This
secures the conductor.
5.1.1.2 Directly Inserting Conductors
The following conductors can be inserted directly without tools:
•
Fine-stranded conductors with insulated ferrules for all permissible cross
sections
•
Fine-stranded conductors with uninsulated ferrules, cross section
> 0.5 mm²/AWG 22
•
Solid conductors with a cross section > 0.25 mm²/AWG 24
P o s : 5 0 . 5 /S e rie 7 8 7 (E P S IT R O N
) /A n sc h lie ß en /A n s ch lü s se 7 8 7- 12 x x - Z ie h e n un d S te c ke n p ic oM A X ® @ 1 9\ m od _ 14 0 05 7 8 28 9 76 8 _2 1 .d o cx @ 15 4 2 92 @ 3 44 5 54 @ 1
5.1.2
WAGO
picoMAX
®
Connectors
WAGO’s
picoMAX
®
pluggable connectors enable you to prewire devices to
expedite device installation and avoid rewiring during device replacement.
The procedure for removal and connection is the same for both WAGO plug
connectors.