34 Commissioning
WAGO Edge Computer
752-940x
Manual
Version 1.1.0
8
Commissioning
Press the ON/OFF button on the front. The device boots with the pre-installed
operating system. The Interface X1 is set with the default IP 192.168.1.17. The
ETHERNET interface X2 is preset to DHCP.
Static IP hidden!
The static IP (manual configuration) only becomes visible when the interface is
enabled.
Network configuration changed!
In Firmware 01 the ETHERNET interface X1 is preset to DHCP and the Interface
X2 is set with the default IP 192.168.1.17.
8.1
Login
The system is pre-set with two users:
Table 23: Default User
Users
Password
edge
wago
root
wago
The first time a user logs on, they are prompted to change the respective
password. The password must be least 6 characters long, have upper and lower
case letters and at least one number.
Change passwords!
Default passwords are documented in these instructions and therefore do not
offer adequate protection! Change the passwords to meet your particular needs.