background image

4  •  

Important Comments
Legal Principles

WAGO-I/O-SYSTEM 750

ETHERNET StarterKit 1

1 Important Comments

To ensure fast installation and start-up of the units described in this manual,
we strongly recommend that the following information and explanations are
carefully read and abided by.

1.1 Legal Principles

1.1.1 Copyright

This manual is copyrighted, together with all figures and illustrations
contained therein. Any use of this manual which infringes the copyright
provisions stipulated herein, is not permitted. Reproduction, translation and
electronic and photo-technical archiving and amendments require the written
consent of WAGO Kontakttechnik GmbH. Non-observance will entail the
right of claims for damages.

WAGO Kontakttechnik GmbH reserves the right to perform modifications
allowed by technical progress. In case of grant of a patent or legal protection of
utility patents all rights are reserved by WAGO Kontakttechnik GmbH.
Products of other manufacturers are always named without referring to patent
rights. The existence of such rights can therefore not be ruled out.

1.1.2 Personnel Qualification

The use of the product detailed in this manual is exclusively geared to
specialists having qualifications in PLC programming, electrical specialists or
persons instructed by electrical specialists who are also familiar with the valid
standards. WAGO Kontakttechnik GmbH declines all liability resulting from
improper action and damage to WAGO products and third party products due
to non-observance of the information contained in this manual.

1.1.3 Intended Use

For each individual application, the components supplied are to work with a
dedicated hardware and software configuration. Modifications are only
permitted within the framework of the possibilities documented in the
manuals. All other changes to the hardware and/or software and the non-
conforming use of the components entail the exclusion of liability on part of
WAGO Kontakttechnik GmbH.

Please direct any requirements pertaining to a modified and/or new hardware
or software configuration directly to WAGO Kontakttechnik GmbH.

Содержание 750-842

Страница 1: ...Modular I O System ETHERNET StarterKit 1 510 370 74 Quick Start ETHERNET Fieldbus Controller 750 842 Version 1 0 1...

Страница 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Страница 3: ...pyright 4 1 1 2 Personnel Qualification 4 1 1 3 Intended Use 4 1 2 Symbols 5 1 3 Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 Quick Start 7 2 1 Node assembly 7 2 2 Ethernet network start up 8 2...

Страница 4: ...r manufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this ma...

Страница 5: ...operation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for effi...

Страница 6: ...he spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assembled in housings cabinets or in electrical operation rooms Ac...

Страница 7: ...412 0001 0101 and on the Internet under www wago com 2 Quick Start 2 1 Node assembly Build up the fieldbus node as follows from left to right 750 842 750 430 750 530 750 600 Connect the supplies for t...

Страница 8: ...s CD Item no 0888 0412 0001 0101 or on the Internet under www wago com Service Downloads Software Click the Edit Bootptab button Create an entry in the bootptab file with the following structure Any n...

Страница 9: ...ed for local addresses Further information Please find more information about avoiding the Proxy server in the browser help section under Proxy server and LAN settings The integrated Web server will n...

Страница 10: ...ile New Example Fig 3 WAGO I O PRO 32 Creating a new POU A new POU PLC_PRG is created using the programming language ST Fig 3 Before programming the controller 750 842 it must be selected This is done...

Страница 11: ...image will then look like the following byte declaration Input_Byte AT IB0 BYTE Output_Byte AT QB0 BYTE Fig 5 WAGO I O PRO 32 Declaration and assignment in the PLC PRG A simple assignment could be Out...

Страница 12: ...CP_IP WAGO Ethernet TCP IP driver Enter the IP address of the coupler under IP Address e g 192 168 1 2 Enter port number 2455 The transport protocol is TCP Please note that the simulation is deactivat...

Страница 13: ...bus TCP DLL it needs to be installed on your computer preferably in the Windows System directory Restart your computer You can find a DLL function description in the API Modbus TCP DLL manual chapter...

Страница 14: ...WAGO Kontakttechnik GmbH Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: