![WAGO 750-652 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/wago/750-652/750-652_manual_3169019076.webp)
76
Appendix
WAGO-I/O-SYSTEM 750
750-652 Serial Interface RS-232 / RS-485
Manual
Version 1.4.0
Table 50: Specific Module / Channel Parameters for 75x-652
GSD File
WAGO-I/O-
CHECK
Description
Value
Selection box
Value
Baud rate
[Baud]
300
Transmission Rate [Baud] 300
1200
Transmission Rate [Baud] 1200
2400
Transmission Rate [Baud] 2400
4800
Transmission Rate [Baud] 4800
9600
*)
Transmission Rate [Baud] 9600
19200
Transmission Rate [Baud] 19200
38400
Transmission Rate [Baud] 38400
57600
Transmission Rate [Baud] 57600
115200
Transmission Rate [Baud] 115200
600
Transmission Rate [Baud] 600
Data bits
8
*)
Data Bits
8
*)
7
Data Bits
7
Parity
none
*)
Parity
none
*)
odd
Parity
odd
straight
Parity
straight
Stop bits
1
*)
Stop Bits
1
*)
2
Stop Bits
2
Flow control
deactivated
*)
Flow Control
disabled
*)
XON/XOFF
Flow Control
XON/XOFF
RTS/CTS
Flow Control
RTS/CTS
RTS, lead/follow-on time
Flow Control
RTS, lead/follow-on
time
Continuous send lock
*)
Continuous Send Mode
disabled
*)
release
Continuous Send Mode
release
Continuous
receive
lock
*)
Continuous Receive Mode disabled
*)
release
Continuous Receive Mode release
Switching time
RS-485
100 us
*)
Switchover Time RS-485 100 us
*)
2 characters
Switchover Time RS-485 2 Characters
4 characters
Switchover Time RS-485 4 Characters
Monitoring time
con. receive
2 characters
*)
Continuous Receive
Tiemout
2 Characters
*)
4 characters
Continuous Receive
Timeout
4 Characters
*)
Default setting
con. = continuous