1 Important Comments 

To ensure fast installation and start-up of the units described in this manual, 
we strongly recommend that the following information and explanations are 
read carefully and followed. 

1.1 Legal Principles 

1.1.1 Copyright 

This manual is copyrighted, together with all figures and illustrations con-
tained therein. Any use of this manual which infringes the copyright provi-
sions stipulated herein, is not permitted. Reproduction, translation and elec-
tronic and photo-technical archiving and amendments require the written con-
sent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail 
the right of claims for damages. 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modi-
fications allowed by technical progress. In case of grant of a patent or legal 
protection of utility patents all rights are reserved by WAGO Kontakttechnik 
GmbH & Co. KG. Products of other manufacturers are always named without 
referring to patent rights. The existence of such rights can therefore not be 
ruled out. 

1.1.2 Personnel 

Qualification 

The use of the product detailed in this manual is exclusively geared to special-
ists having qualifications in PLC programming, electrical specialists or per-
sons instructed by electrical specialists who are also familiar with the valid 
standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability re-
sulting from improper action and damage to WAGO products and third party 
products due to non-observance of the information contained in this manual. 

1.1.3 Intended 

Use 

For each individual application, the components supplied are to work with a 
dedicated hardware and software configuration. Modifications are only per-
mitted within the framework of the possibilities documented in the manuals. 
All other changes to the hardware and/or software and the non-conforming use 
of the components entail the exclusion of liability on part of WAGO Kon-
takttechnik GmbH & Co. KG. 

Please direct any requirements pertaining to a modified and/or new hardware 
or software configuration directly to WAGO Kontakttechnik GmbH & Co. 
KG. 

Содержание 750-644

Страница 1: ...Fieldbus Independent I O Modules Bluetooth RF Transceiver 750 644 Quick Start Version 1 0 1...

Страница 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Страница 3: ...4 1 1 3 Intended Use 4 1 2 Symbols 5 1 3 Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 Quick Start 7 2 1 Network Structure 7 2 2 Starting up the Bluetooth Modules 9 2 2 1 Configuration of the Blu...

Страница 4: ...facturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual i...

Страница 5: ...D Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe precautionary measures for handling components at risk Note Routines or advice for efficient use of the...

Страница 6: ...ng of the contact area The WAGO I O SYSTEM 750 and its components are an open system As such the system and its components must be installed in appropriate hous ings cabinets enclosures or in electric...

Страница 7: ...750 600 End Module 2 Connect one of the controllers to a free serial port of your PC using a WAGO communication cable 750 920 3 Connect the second controller in the same manner to another PC serial po...

Страница 8: ...8 Quick Start Network Structure WAGO I O SYSTEM 750 I O Modules Figure 1 Hardware configuration g064461e...

Страница 9: ...slave 0 0 0 6 C 6 _ _ _ _ _ _ Write down the MAC address of the master 0 0 0 6 C 6 _ _ _ _ _ _ 2 2 1 Configuration of the Bluetooth Slave Using Net Forming 1 Start the WAGO I O CHECK software Version...

Страница 10: ...the following the Bluetooth module s must remain intact i e no con figuration attempts have been attempted If this is not the case click on the Default button to restore the module to factory default...

Страница 11: ...the list of devices within range see Figure 5 The MAC address of the slave itself is not displayed in this dialog Figure 5 Net forming g064463e 10 Search in the list for the MAC address of the master...

Страница 12: ...ee Figure 6 Figure 6 Bind device g064464e 15 Click on the Write button in the toolbar to write the altered configura tion in the module You have now allocated a master to the Bluetooth slave Slave Mas...

Страница 13: ...ion of the module Attention For the following the Bluetooth module must remain intact i e no configu ration attempts have been attempted If this is not the case click on the De fault button to reset t...

Страница 14: ...or search request in communi cation operating mode they may also be entered like other hidden devices or inaccessible devices 10 Enter the listed MAC address of the slave which is already set in the c...

Страница 15: ...tion choose the menu item PI Mapping The process data allocation is loaded from the module and graphically dis played in WAGO I O CHECK 4 Move the ruler for the first slave to the right so that the fi...

Страница 16: ...after the other 3 Choose Process data in the context menu The process data dialog opens so that you can view the raw data 4 Click with the right mouse button on the word Input in the dialog of the mas...

Страница 17: ...Quick Start 17 Testing the Process Data Exchange WAGO I O SYSTEM 750 I O Modules...

Страница 18: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Telefon 05 71 8 87 0 Telefax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: