1.4 Safety Notes 

 

Attention

 

Switch off the system prior to working on bus modules! 
 
In the event of deformed contacts, the module in question is to be replaced, as 
its functionality can no longer be ensured on a long-term basis. 
 
The components are not resistant against materials having seeping and insu-
lating properties. Belonging to this group of materials is: e.g. aerosols, sili-
cones, triglycerides (found in some hand creams). 
 
If it cannot be ruled out that these materials appear in the component envi-
ronment, then additional measures are to be taken:  
- installation of the components into an appropriate enclosure 
- handling of the components only with clean tools and materials. 

 

Attention

 

Cleaning of soiled contacts may only be done with ethyl alcohol and leather 
cloths. Thereby, the ESD information is to be regarded. 
 
Do not use any contact spray. The spray may impair the functioning of the 
contact area.  
 
The WAGO-I/O-SYSTEM 750 and its components are an open system. It 
must only be assembled in housings, cabinets or in electrical operation 
rooms. Access must only be given via a key or tool to authorized qualified 
personnel. 
 
The relevant valid and applicable standards and guidelines concerning the 
installation of switch boxes are to be observed.  

 

ESD

 (Electrostatic Discharge) 

The modules are equipped with electronic components that may be destroyed 
by electrostatic discharge. When handling the modules, ensure that the envi-
ronment (persons, workplace and packing) is well grounded. Avoid touching 
conductive components, e.g. gold contacts. 

 

1.5 Scope 

This manual describes the Digital Output Module 

750-512

 

2DO 230V AC 2.0 A/ Relay

 2NO of the modular WAGO-I/O-SYSTEM 750. 

Handling, assembly and start-up are described in the manual of the Fieldbus 
Coupler. Therefore this documentation is valid only in the connection with the 
appropriate manual. 

Содержание 750-512

Страница 1: ...Fieldbus Independent I O Modules 2DO 230V AC 2 0 A Relay 2NO 750 512 Manual Version 1 0 2...

Страница 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Страница 3: ...Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Digital Output Modules 7 2 1 1 750 512 2DO 230V AC 2 0 A Relay 2NO 7 2 1 1 1 View 7 2 1 1 2 Description 7 2 1 1 3 Display Elements...

Страница 4: ...nufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual...

Страница 5: ...ation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient...

Страница 6: ...information is to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assemb...

Страница 7: ...relay contacts from the control system The module has two output channels Two actuators with ground earth wire may be directly connected to signal output DO 1 N and PE earth potential or signal output...

Страница 8: ...10 A When configuring the system it is important not to exceed the maximum sum cur rent However if such a case should occur another supply module must be added Note For the protection of relay coils a...

Страница 9: ...2NO 9 Schematic Diagram WAGO I O SYSTEM 750 I O Modules 2 1 1 4 Schematic Diagram DO 2 AC 230 V DC 30 V AC 230 V DC 30 V DO 1 N N 0 V 0 V DO Status 1 2 3 4 5 6 7 8 750 512 Fig 2 1 1 3 2 Channel Relay...

Страница 10: ...10 ms Contact material Silver alloy Mechanical life max 2x107 switching operatins Electrical life min 3x105 switching operatins AC 2 A 250 V or DC 2 A 30V Isolation 1 5 kVeff System Field 2 5 kV rate...

Страница 11: ...Bureau of Shipping BV Bureau Veritas Conformity Marking More Information Detailed references to the approvals are listed in the document Overview Approvals WAGO I O SYSTEM 750 which You can find on th...

Страница 12: ...O Modules 2 1 1 7 Load limiting value graph of the relay 0 0 1 0 3 0 5 1 3 5 10 30 50 3 5 10 30 100 250 500 1000 Switching current A Switching voltage V AC load resistive AC in ductive load cos 0 4 j...

Страница 13: ...ar Effective Attenuation Advantages Disadvantages Diode UD Load g051211e long yes UD no Advantages easy implementation cost effective reliable uncritical dimensioning low induction voltage Disadvantag...

Страница 14: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: