2789-9080
Fieldbus Description
| Version: 1.1.0
17
Communication Module IO-Link
4.2 Parameters
4.2.1 General Module Parameters
The product uses the following default IO-Link parameters:
Table 14: Standard parameters of IO-Link
Index Subin
dex
Parameters
Data Type
Daten-
länge
(Bytes)
Description
12
0
Device Access Locks
RecordT
2
Standardized Device lock-
ing functions
13
0
Profile
Characteristic
ArrayT of
UIntegerT16
2
Profile characteristic
14
0
PDInput Descriptor
ArrayT of
OctetStringT3
3
Reserved for Device pro-
file
15
0
PDOutput
Descriptor
ArrayT of
OctetStringT3
3
Reserved for Device pro-
file
16
0
Vendor Name
StringT
32
Informative
17
0
Vendor Text
StringT
32
Additional vendor informa-
tion
18
0
Product Name
StringT
32
Detailed product or type
name
19
0
Product ID
StringT
32
Product or type identifica-
tion
21
0
Serial Number
StringT
16
Description of Device func-
tion or characteristic
22
0
Hardware Revision
StringT
5
Vendor specific serial
number
23
0
Firmware Revision
StringT
8
Vendor specific format
24
0
ApplicationSpecific Tag
StringT
32
Vendor specific format
25
0
Function Tag
StringT
32
Tag location or tag func-
tion defined by user
26
0
Location Tag
StringT
32
Standardized Device lock-
ing functions
36
0
Device Status
UIntegerT
1
Contains current status of
the Device
37
0
Detailed Device Status
ArrayT of
OctetStringT3
96
40
0
ProcessDataInput
32
Read last valid Process
Data from PDin channel
41
0
ProcessDataOutput
32
Read last valid Process
Data from PDout channel
For more information on these default parameters, see:
• IO-Link Interface and System Specification Version 1.1.2 Table B.8
• IO-Link Common Profile Specification Version 1.0 Table B.1