12. 

 

Selecting the Spray Setting  

(WallPerfect I-Spray spray attachment)

WARNING! Danger of injury! Never pull the trigger guard while adjusting 

the air cap.

2 different spray jet shapes can be set by turning the adjustment ring (fig. 10, 1)

Fig. 11 A

 = vertical flat jet

for horizontal surfaces

Fig. 11 B

 = horizontal flat jet

for vertical surfaces

13. Adjusting the Material Volume (Fig. 7, item 3)

Set the material volume by turning the regulator on the trigger guard of the spray gun.
- turn to the left     

 

lower material volume

+ turn to the right 

  

higher material volume

14. Setting the Amount of Air (Fig. 7, item 1)

Depending on the viscosity of the material to be sprayed and the finish of the object to be 

coated, it may be advisable to vary the amount of air. Very low viscosity materials, such as 

watery glazes do not have to be atomised with the maximum amount of air. In this case it 

is advisable to reduce the amount of air and thus minimize the spray vapour.
This also applies for the use of the low-scale and radiator/detail spray attachment 

(accessory).
- turn to the left  

 

lower amount of air

+ turn to the right  

 

higher amount of air

15. 

 

Spray Technique

i

The spray result depends heavily on the smoothness and cleanliness of the 

surface to be sprayed. Therefore the surface should be carefully prepared and 

kept free of dust.

• 

Cover all surfaces not to be sprayed. 

• 

Cover screw threads or similar parts of the target object.

i

Important: Start at the edge of the area to be sprayed. Start the spray 

movement first of all, and then press the trigger. Avoid interruptions 

within the area to be sprayed.

Содержание WallPerfect Flexio 867

Страница 1: ...2year Guarantee WallPerfect Flexio 867 D GB F NL...

Страница 2: ...25 26 9 12 11 18 23 22 27 21 29 28 7 8 6 4 5 3 19 1 2 13 14 17 16 15 20 30 31 Testposter 20 30 cm 0 10 Materialnr 233 0627 EBSS A B C D E F Cover up 2 4 3 3 3 1 1 4 1 3 1 2330627_Testposter_W565 indd...

Страница 3: ...Flexio 867 f e A B d c...

Страница 4: ...Flexio 867 g 2 2 1 1 3 A B C 1 A B...

Страница 5: ...Flexio 867 A C 20 30 cm B A A B C A...

Страница 6: ...Flexio 867 1 2 3 4 5 2 3 4 1 2 3 5 4 6...

Страница 7: ...Flexio 867 1 1 2 3 4 5 6 7 8 9 10 1 2 7 8 3 4 5 6 9...

Страница 8: ...Flexio 867 1 2 4 5 3 6 7 8...

Страница 9: ...ctions for Spray Guns 5 4 Description Scope of delivery 6 5 Field of application 7 6 Coating Materials Suitable for Use 7 7 Coating Materials Not Suitable for Use 7 8 Preparation of the workplace for...

Страница 10: ...articularly well suited for use with the relevant device Devices and accessories marked with this symbol are suitable for processing high viscosity materials such as e g interior wall paints dispersio...

Страница 11: ...ted leads increase the risk of an electric shock e If you work outdoors with a power tool only use extension cables suitable for outdoor use The use of an extension lead that is suitable for outdoors...

Страница 12: ...and safer in the specified performance range if you use the suitable power tool b Do not use power tools whose switch is defective A power tool that cannot be switched on or off is dangerous and has t...

Страница 13: ...rking clothing safety glasses ear protection and gloves CAUTION Danger of injury Never point the spray stream towards human beings or animals Sockets and plugs must be masked Risk of an electric shock...

Страница 14: ...d With originalWAGNER accessories and spare parts you have the guarantee that all safety regulations are fulfilled 4 Description Scope of delivery Description Scope of delivery Figs 1 2 1 Air cap 2 No...

Страница 15: ...Suitable for Use Interior wall paint dispersions and latex paint Water and solvent based paints finishes primers 2 component paints clear finishes automotive finishes staining sealers and wood sealer...

Страница 16: ...r if the flow rate is too low even at the maximum setting Detailed information about the various materials and the maximum permitted dilutioncanbefoundonthemanufacturers technicaldatasheets e g availa...

Страница 17: ...10 Place the device only on a plane and clean surface Otherwise the gun may suck in dust etc 11 Switch on the main switch at the device Fig 1 item 14 12 Remove the spray gun from the gun holder and po...

Страница 18: ...ct to be coated it may be advisable to vary the amount of air Very low viscosity materials such as watery glazes do not have to be atomised with the maximum amount of air In this case it is advisable...

Страница 19: ...w first paint coat to dry first This will ensure good coverage 16 Interruption of Work till 4 Hours Turn the machine off During longer breaks vent the container by briefly opening and then closing it...

Страница 20: ...the union nut and remove the air cap and nozzle Clean the air cap nozzle seal and nozzle with a brush and solvent or water Fig 16 4 Clean the outside of the spray gun and container with a cloth soaked...

Страница 21: ...Assembly Assembly The unit may only be operated with an integer diaphragm Fig 15 C 1 Place the diaphragm Fig 15 C with the pin facing upwards on the bottom section of the valve Also see the marking o...

Страница 22: ...se and when storing it in the cover put in the gun handle first 22 Spare Parts Spare Parts List Perfect Spray spray attachment Fig 24 Pos Designation Order No Perfect Spray spray attachment complete w...

Страница 23: ...t included in the delivery Name Order No HVLP handle extension For easier coating of ceilings and horizontal objects 2307 678 Container with cover 800 ml Ensures that the paint does not dry out and th...

Страница 24: ...pay special attention to the instructions on the product packaging 25 Important Note regarding Product Liability Due to an EC ordinance in effect since 01 01 1990 the manufacturer is liable for his p...

Страница 25: ...ed Turn material volume adjusting screw to the left Too much fog of coating material Overspray Distance to the object too large Too much coating material applied Amount of air too high Reduce distance...

Страница 26: ...lation level The specified oscillation level has been measured according to a standard test procedure and can be used to compare against electric tools The oscillation level is also for determining an...

Страница 27: ...arantee expires if the tool is opened up by persons other than WAGNER service personnel Transport damage maintenance work and loss and damage due to faulty maintenance work are not covered by the guar...

Страница 28: ...20 Flexio 867 AUS...

Страница 29: ...21 Flexio 867 AUS...

Страница 30: ...7 321 36 22 407 852 DK S Wagner Spraytech Scandinavia A S Helgesh j All 28 DK 2630 T strup 45 43 27 18 18 45 43 43 05 28 E J Wagner Spraytech Ib rica S A Ctra N 340 Km 1245 4 08750 Molins de Rei Barce...

Отзывы: