16
W 180 P
GB
7, arrow). Briefly switch on the spray gun.
i
The spray gun can only operate satisfactorily if it is cleaned and preserved
after each use.
Accessories W 180 P (not included in scope of delivery)
Designation
Order No.
Paint container with cover
0413 909
Needle-jet nozzle
0209 045
Flexible nozzle extension with atomiser
For spraying ceilings, resting objects or hard-to-reach areas e.g. radiators
0046 675
Spare Parts List (Illus. 9)
Pos
Name
Order No.
1
Suction tube
0413 305
2
Paint container with cover
0413 909
3
Nozzle 0,8 mm
0046 903
4
Locking nut
0413 310
5
Valve
0209 042
6
Pump housing
0413 202
7
Piston spring
0033 028
8
Piston
0198 207
9
Nozzle spanner
0199 327
10
Viscosity measuring cup
0209 058
Correction of Malfunctions
Problem
Cause
Remedy
Spray gun buzzes
and does not work
•
Piston stuck
•
Defective drive
➞
Disassemble pump and
clean with thinner
➞
Please contact Wagner
Service
Spray gun does not
suck in
•
No valve in the pump
•
Suction tube loose in the
conical bore
•
Venting hole in pump housing
clogged
•
Intake hole (fitting) in
pumphousing logged
•
Viscosity of spray material too
high
➞
Insert valve
➞
Adjust suction tube
➞
Clean
➞
Clean
➞
Thin accordingly