41
TempSpray-H326 / -H226 / -H126/ -H426
GB
5
HaNDLiNG THe HiGH-PreSSure
HOSe
The high-pressure hose is to be handled with care. Avoid sharp
bending or kinking. The smallest bending radius amounts to
about 20 cm (80 cm for TempSpray H426).
Do not drive over the high-pressure hose. Protect against
sharp objects and edges.
Danger of injury through leaking high-
pressure hose. Replace any damaged high-
pressure hose immediately.
Never repair defective high-pressure hoses
yourself!
When using the high-pressure hose while
working on scaffolding, it is best to always
guide the hose along the outside of the scaf-
folding.
6
iNTerruPTiON OF WOrk
Release the pressure in the hose and switch off the heating
during longer breaks.
In using quick-drying or two-component
coating materials, do not fail to rinse unit
through with a suitable cleaning agent dur-
ing the processing period.
Important: The application life of the material
can change as a result of heating. Therefore,
please consult the material manufacturer.
7
cLeaNiNG THe DeVice
A clean state is the best method of ensuring operation with-
out problems. After you have finished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit.
Clean the device with an adequate detergent, after finishing
the paint work.
The solvent used for cleaning (with a flash point over 21 °C)
has to be adequate to the coating material.
While cleaning with solvents (except water)
-> always switch off heating.
7.1
cLeaNiNG THe uNiT FrOM THe OuTSiDe
First unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingression! Never spray down the unit with
high-pressure or high-pressure steam clean-
ers.
Wipe unit externally with a piece of cloth, which has been im-
mersed in a suitable cleaning agent.
The container must be earthed in case of
coating materials which contain solvents
(except water).
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
When cleaning without a nozzle, reduce the
pressure to approx. 20 bar.
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
Therefore the heating can stay switched on.