6
T 25 K
GB
3
2
1
Turn mixing pipe (1, fig. 9) back onto the container as far as
11.
it will go. Secure mixing pipe with linch pin (2).
1
2
Clean container.
12.
Pull back latching bolts (1, fig. 10).
Take up position in front of the device (2).
Hold device with handle (3) and turn in the direction of
the arrow until safety hook (4) stops.
Release safety hook (4).
Slowly turn device in the direction of the arrow (180°) to
empty completely.
Achtung
Caution: Remember the weight of the device.
1
0
2
Autom.
Aus
Hand
1
3
2
5
4
Then turn the device back into its operating position.
Take care that the latching bolts engage in the trolley
frame.
If coating material still remains in the container:
13.
Unscrew hexagon nut (5, fig. 10) and remove protective
grid.
Dry container and dosing section and clean with a brush.
Re-fit the protective grid.