background image

 

500-62201-001 Rev. M  

Page 17 of 33    

 

 

 

Group Report 

 

 

Group Summary Report 

 

 

Readings Report 

 

 

Operation 

 
 
 
 
 
 
 

 
Enter the Print menu and activate the 
Group item.   
 
Press the 

ARROW

 buttons to select the 

group to print. 
 
Press the 

STORE

 button to send the 

group report to the printer. 

 
Enter the Print menu and activate the 
Summary item.   
 
Press the 

STORE

 button to send the 

report to the printer. 
 

 
Enter the Print menu and activate the 
Readings item.   
 
Press the 

ARROW

 buttons to select the 

group to print. 
 
Press the 

STORE

 button to send the 

readings  report to the printer. 

Display 

 
Group 
   0 

 
Print 
Summary 

 
Group 
   0 

 

STORE

 

 

 
Press the 

STORE

 button to send the 

report to the printer. 

 
Press the 

STORE

 button to send the 

report to the printer. 

 
Press the 

STORE

 button to send the 

report to the printer. 

 

GROUP

 

 

 
Press the 

GROUP

 button to advance to 

the next valid group. 

 
Press the 

GROUP

 button to return to 

the readings mode. 

 
Press the 

GROUP

 button to advance to 

the next valid group. 

 

MENU

 

 

 
Press the 

MENU

 button to cancel and 

return to the readings mode. 

 
Press the 

MENU

 button to send the 

report to the printer. 

 
Press the 

MENU

 button to cancel and 

return to the readings mode. 

 

ARROWS

 

 

 
Press the 

ARROW

 buttons to 

increment or decrement the group 
number. 

 
Press the 

ARROW

 buttons to 

increment or decrement the menu. 

 
Press the 

ARROW

 buttons to 

increment or decrement the group 
number. 

Содержание L622

Страница 1: ...WAGNER MODEL L622 DIGITAL RECORDING HAND HELD MOISTURE METER OWNER S MANUAL DOCUMENT NO 500 62201 001 REV M...

Страница 2: ...y any means without the express written permission of Wagner Meters Technical Support Should you require support please consult your printed documentation to resolve your problem If you are still expe...

Страница 3: ...Std Statistics 13 High Low Statistics 13 Clear Menu 14 Clear Group 15 Clear Readings 15 Clear All Groups 15 Printing Reports 16 Group Report 17 Group Summary Report 17 Readings Report 17 Sample Group...

Страница 4: ...an outlet on a circuit different from that to which the receiver powered If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions CAUTI...

Страница 5: ...ture readings are virtually unaffected by wood temperature in the normal operating range outside of a kiln environment Refer to the stack probe manual for more information about measuring wood in kiln...

Страница 6: ...group is a set of readings that belong together You determine which readings belong together Switch to another group by first pressing the GROUP button Press the ARROW buttons to select a different n...

Страница 7: ...rrent reading and the active group number When a reading is above 5 the first line becomes a bar graph representing the current reading When storing a valid reading the second line will display the me...

Страница 8: ...menu item Locale Species Mean Std High Low Clear Print Calibration Backlight Battery Display Group 1 Menu Language STORE Press the STORE button to save the change and return to the readings mode Press...

Страница 9: ...are dependent on your locale Press the STORE button to activate the language for the meter text Display Locale Language Language English STORE Press the STORE button to activate the selected menu item...

Страница 10: ...item MM DD YY DD MM YY Selecting the MM DD YY item will format the date in the month day year order Selecting the DD MM YY item will format the date in the day month year order Display Date MM DD YY S...

Страница 11: ...nu item Period Comma Selecting the Period format will use the period character as the decimal separator Selecting the Comma format will use the comma character as the decimal separator Display Decimal...

Страница 12: ...tivate changes Display Species SG Walnut Black 41 Edit SG Walnut Black 45 Edit Name Walnut Black 45 STORE Press the STORE button to activate the selected species Press the STORE button to save and act...

Страница 13: ...contain readings will be shown Press the STORE button to return to the readings mode Display Mean Std GRP 8 3 4 7 0 High Low GRP 11 0 6 1 1 STORE Press the STORE button to return to the readings mode...

Страница 14: ...through the Clear menu Press the STORE button to activate the selected item Group Readings All Groups Display Clear Group STORE Press the STORE button to activate the selected item GROUP Press the GR...

Страница 15: ...nd return to the readings mode Display Group 0 Reading GRP 17 6 10 21 All Groups Yes STORE STORE Press the STORE button to clear the selected group Press the STORE button to clear the selected reading...

Страница 16: ...hrough the Print menu Press the STORE button to activate the menu item Group Summary Readings Display Print Group STORE Press the STORE button to activate the selected menu item GROUP Press the GROUP...

Страница 17: ...Summary Group 0 STORE Press the STORE button to send the report to the printer Press the STORE button to send the report to the printer Press the STORE button to send the report to the printer GROUP...

Страница 18: ...roup Report Company Name Meter 1 First 10 10 07 07 14 10 Last 10 18 14 07 14 10 Group Readings Mean Std High Low Species SG 0 32 11 9 2 3 15 1 5 6 Douglas Fir 50 Readings Total Histogram 0 0 6 2 6 2 8...

Страница 19: ...Readings Mean Std High Low Species SG 0 32 11 9 2 3 15 1 5 6 Douglas Fir 50 7 36 14 3 4 0 24 0 6 8 Douglas Fir 50 11 35 13 2 3 0 19 2 7 5 Douglas Fir 50 199 31 12 8 3 4 22 3 7 9 Douglas Fir 50 4 134 1...

Страница 20: ...14 07 14 10 Group Readings Mean Std High Low Species SG 0 32 11 9 2 3 15 1 5 6 Douglas Fir 50 1 12 3 2 12 3 3 12 6 4 13 9 5 15 1 6 14 8 7 14 4 8 13 0 9 12 4 10 12 2 11 11 3 12 10 6 13 10 3 14 9 7 15...

Страница 21: ...ol dry place Follow these steps for checking calibration 1 Enter the Calibration verification mode using the MENU button 2 Hold the L622 in mid air so the bottom is several feet from any object The co...

Страница 22: ...list Press the STORE button to restore factory settings Press the GROUP or MENU button to cancel operation and return to the readings mode Display Backlight ON xxxxxx 4 0 Volts Factory Yes STORE STOR...

Страница 23: ...readings in up to 200 groups Groups are numbered 0 to 199 and can be selected at random There is no limit to the number of readings per group as long as the total readings of all groups do not exceed...

Страница 24: ...e 4 Convert the weight to pounds or kilograms lb or kg 5 Calculate specific gravity SG An English units illustration Length 10 in converted to feet is 10 in 12 0 833 ft Width 7 5 in converted to feet...

Страница 25: ...Additionally the following resources are available to obtain specific gravity values for species not found in the L622 and Stat Pak software http www wagnersg com http www fpl fs fed us utilities info...

Страница 26: ...Handbook The exception may be caused by unknown biases in the sampling scheme The Wood Handbook values are used in the species list Species correction can be determined for lumber sorted or otherwise...

Страница 27: ...1 stop bit Plug one end of the modular serial cable into the COMM port of the L622 Plug the other end into the DB25P to RJ11 modular adapter Plug the DB25P to RJ11 adapter into the serial printer Foll...

Страница 28: ...tro magnetic wave technology and are sensitive to changes in density and the actual moisture content of the wood Q What is the narrowest piece of lumber I can measure accurately with the Wagner Hand H...

Страница 29: ...sible Once the standing water is removed Pin type meters with non insulated pins will register a highly exaggerated moisture reading Wagner Hand Held Moisture Meters will read slightly higher than nor...

Страница 30: ...ngs with pin type or Wagner Hand Held Moisture Meters Note However if you would like to work up your own calibrations for materials you use repetitively you can contact Wagner for guidelines and sugge...

Страница 31: ...s proper moisture content in wood What moisture content is considered too high or too low A There is no one correct answer for this question As a rule differences in woods and their uses determine the...

Страница 32: ...ed in the manual the meter should stay in calibration however because Wagner Meters has no control over the manner in which the unit will be used it makes no warranty that the meter will stay in calib...

Страница 33: ...41 582 0541 Fax 541 582 4138 Standard repairs Customer must pay the expense of shipping the product to and from Wagner Warranty repairs Customer must pay the expense of shipping the product to Wagner...

Отзывы: