EN
11
MAINTENANCE
CLEANING THE FILTER
Attention
Before every use, you should inspect the air filter
in the turbine to see if it is excessively dirty. If it is
dirty, follow these steps to replace it.
Never operate your unit without the air filters. Dirt
could be sucked in and interfere with the function
of the unit.
1.
Press the tabs at the rear of the turbine. Slide the rear housing off
of the back of the turbine.
2.
Remove the dirty filter from the turbine and replace with a new
one. The smooth side of the air filter must be placed toward the
turbine.
Secure the cover back onto the turbine.
i
If spray material ever enters the air valve tube,
follow the steps below.
1.
Pull the air tube (a) at the top from the nozzle. Screw off the valve
cover (b).
Remove the valve seal (c). Clean all the parts carefully. Make sure
to remove any material from valve seal housing area (d).
Attention
The air tube and valve seal (c) are only solvent-
resistant to a limited extent. Do not immerse in
solvent, only wipe.
2.
Place the valve seal (c) in the valve cover (b) with the pin facing
into the tube. Installing the valve seal into the valve cover will be
much easier if the valve cover is inverted.
3.
Turn the nozzle upside down and screw on the valve cover (with
valve seal inside) from underneath. Turning the nozzle upside
down will prevent the valve seal from falling out of the valve cover
during reinstallation.
4.
Place the air tube on the valve cover and on the nipple at the
nozzle.
CLEANING THE AIR VALVE TUBE
PRESS
1
(a)
(b)
(c)
(d)
2
(c)
(b)
3
4
Содержание CONTROL SPRAY QX5
Страница 16: ...CONTROL SPRAY QX5 www wagnerspraytech com...