10.5 DISASSEMBLING VM 5020W CONTROL UNIT
1. Switch off control unit.
2. Open cabinet door (1) (pull hard).
3. Lock the compressed air supply and decompress the system.
4. Loosen and unscrew screws (2).
5. Carefully remove control unit (3) forwards. Note the connecting lines and connecting
cables at the back of the control unit!
B_05899
1
2
3
2
10.6 OPENING THE CONTROL UNIT
1. Dismount the control unit from the AquaCoat system
(see Chapter
1
2
B_06169
2. Place control unit on a suitable surface.
3. Loosen and unscrew screws (1).
4. Remove cover (2) from housing.
5. When the repair is complete, replace the cover (2)
on the housing and fasten with the screws (1).
Attention: Connect the grounding cable to
the cover.