51
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
6.6.5 FILLING THE SYSTEM
NOTICE
Interchange of the two components A and B!
Device damage by hardened product.
Label device components and paint tank so that the components A and B are not
mixed up.
Menu
(see Chapter
)
Example for a hardener valve with the name B1:
1. Prepare the hardener components' tank and put the suction pipe in the respective
pump.
2. Select [B] components, then select valve B1.
Open the valve with the large valve button.
3. Set the hardener pump slightly under pressure. Open the hardener valve with the
large valve button.
4. Point the guns into the grounded metal bucket and open it step by step. Avoid
splashback.
5. After the hardener is filled, calibrate the hardener straight away, if necessary, according
to Chapter
6. Close the valve via the [Valve] field or close the STOP button again.
Then, in the same way, fill the system with the other components.
Note:
The solvent used for the first cleaning may not be used again since it might contain oil
residues.
Calibration
Components with flow meter:
− In all paint recipes, calibrate the components as well as the flushing agent.
If the components were already calibrated during filling, the K factors must be entered
in the different recipes.
In accordance with Chapter
.
Components with Coriolis measuring system:
− K factor = Enter 60 ,000 Imp/l according to Chapter
Perform zero point adjustment in accordance with "Coriolis Compact" user information
(Order No., see Chapter
)
6.6.6 ELECTROSTATICS
With an electrostatic gun:
Commissioning the electrostatics according to the corresponding assembly manual.