59
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
7.8
MANUAL MODE: OPEN VALVES
The buttons with reversed colors show our
current location:
Select paint recipe (for A/B/C/D).
Or select flushing valve (for A/B/C/D flushing valves).
Menu
Status of selected valve
Manual operation
Valves
Touch to change
Current flow
Flow rate since
the valve was last
opened
Set product
pressure.
(Only with
"Automatic product
pressure regulator"
option, see Chapter
.)
Open several valves / output
signals at the same time
With password level 3,
see Chapter
.
Leak inspection
(only for piston pumps with
stroke sensor)
see software documentation
B_06467
Leak
inspec.
Menu
cc / min
Q
cc
Vjob
Output
A
B
C
D
A
B
C
D
bar
Valve is closed
Valve is open
Displays list of A/B/
C/D flushing valves.
Select component
A/B/C/D.
Valve used by paint recipe.
(See other used valves: buttons A/B/C/D.)
Manual mode is used for troubleshooting or to fill a pump, for example.
Only one valve can be opened at any one time. If another valve is touched, the controller
closes all valves.
With a gun flush box, the valve for the gun is also opened: either for gun 1 (if gun 1 or 1+x
is selected on the home page), or for gun 2 (if gun 2 is selected on the home page).
Ext. flushing agent
The valve for the external flushing agent can not be opened on this page. If necessary, the
calibration function can be used for this, without saving the measured value (password
level 2, Chapter
).