4.5 Electrical connection
4.5.1 Mains-powered operation
Have a qualified electrician make the electrical connection to the sensor paper roll towel dispenser in order to ensure
about the product is connected in compliance with safety regulations.
In rooms with showers and bathtubs, the product may not be installed in the safety zone specified in VDE regulations (0.6
m from the shower cubicle or bathtub and 1.2 m from the shower heads). This roll-fed hand towel dispenser must be
installed beyond the reach of individuals using a bathtub or shower.
Connect the mains cable directly to the connection terminals provided in the product.
Mains connection: 1N AC 230 V 50 Hz
A disconnect device that guarantees disconnection of all phases through contact separation of at least 3 mm per phase
must be provided at the installation site.
The mains connection must be protected by a residual current protective device.
The mains voltage and voltage data on the product identification plate must agree.
In rare cases of strong electromagnetic fields in the range of 440 kHz +/- 40 kHz, it is possible that the sensor might be
actuated and initiates a single dispensing cycle. The dispenser should be ready to use again immediately once the
disturbance no longer exists. To prevent erroneous actuation from occurring again, reduce the sensor range until the
disturbance disappears.