How to set the monitor panel on
In default mode,when receive a calling,the master and slave monitors will ring at the
same time,and just the master monitor can display the image while the slave monitors
can not.But the settings can be changed,you can set the master monitor and all the slave
monitors to panel on at the same time when receiving a call, just input the code number
of 8006 on each slave monitor.
How to set the unlock parameter
There are two unlock modes: 1.power-on- to-unlock type:unlock mode=0(by default)
2.power-off-to-unlock:unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1
Unlock mode:
Note:1. During talking or monitoring state, UNLOCK
button,two unlock icons will be showed. Use▲ /▼
button to select the item you want, and press UNLOCK
or MENU button to release the corresponding door,select
item to exit.
2. Restore to default operation will not chang the
parameters setting.
The unlock time can be changed by yourself at any time.it can be set from 1 to 9 seconds.
The code number from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds.
The monitor can be set to control 2 locks while you should set the unlock2 item to "on "
state.
The code number of 8015 is used to set the unlock2 off that it can only control one lock.
The code number of 8014 is used to set the unlock2 on
that it can control two locks.
Unlock time:
2 locks control