Wagner & Co EURO C22 Скачать руководство пользователя страница 11

 
EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 

11

Figure 28  Fix upper flashing sheets on the batten using 2 fixing clips.

Figure 29  Position the roof-tile supporting bar by vertically shifting it, 
so that later the tile row will be aligned with the tiles on the sides. Then 
affix with metal strips to roof battens.

Figure 30  Affix black foam rubber tape along the fold to the upper 
flashing sheet.

Figure 31  Secure every flashing sheet with 2 additional sheet metal 
screws each.

Figure 32  Affix foam rubber tape along the folds of the side panels 
as well.

Figure 33  Roof tiles above the collectors may have to be cut to size. 
Drill holes into the pieces that have to be attached, and screw to bat-
tens.

Содержание EURO C22

Страница 1: ...ing Pipe connections protected under upper cladding sheets 1 also applies to EURO 22 Content 1 General Safety Notes 2 1 1 Symbols 2 1 2 Norms and Regulations 2 1 3 Qualification of the Installer 2 1 4...

Страница 2: ...otective film and lay down collectors with glass pane up Avoid direct ground contact e g underlay square timber Avoid scratches on glass panes by using spacers between collectors e g wooden laths When...

Страница 3: ...Risk of melting and damage to absorber Remove glass protection PE LD film before commenc ing installation work figure 4 1 6 Recycling Note At the end of the long operational lifetime the valuable mat...

Страница 4: ...Profile 1 819 450 10 12 Sheet fixing clip 10 181 060 00 13 Flashing sheet bottom left 1 819 721 54 14 Flashing sheet bottom right 1 819 721 56 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 Table 1 cont 15...

Страница 5: ...ing clip top 2 190 102 15 7 Silicone T Profile 1 819 450 10 8 Sheet fixing clips 2 181 060 00 9 Flashing sheet bottom 1 819 721 55 10 Supporting lath 1158 mm 1 819 920 54 11 Supporting laths for roof...

Страница 6: ...e quired the roof tiles have to be shortened For best results properly utilize the flexible space below the collector distance to lower tile row between 60 and 130 mm Figure 7 Dimensions of installati...

Страница 7: ...ax four collectors in serial connection Connection of more than four units by combining parallel and serial connection Figure 8 In roof installation longitudinal section upper drawing and cross sectio...

Страница 8: ...uts with ap propriate tape Figure 12 1 Afix supporting laths with selft tapping screws 4x70 ends projecting approx 100 mm 2 Insert Collectors approx 8 mm distance between collectors Figure 13 Insert s...

Страница 9: ...r cable insert solar sensor into sensor sleeve close opening with rubber seal and lead cable through roof Figure 19 Position wooden support along collector and fasten with 4 x 35 and 5 x 120 self tapp...

Страница 10: ...he flashing sheet must latch into the outer groove of the collector frame see highlighted details Figure 27 Stick additional flashing sheets together to connect them Figure 23 Push lower panel section...

Страница 11: ...the tiles on the sides Then affix with metal strips to roof battens Figure 30 Affix black foam rubber tape along the fold to the upper flashing sheet Figure 31 Secure every flashing sheet with 2 addi...

Страница 12: ...ure 34 Along the side panels the retaining edge or nose of the roofing tiles may have to be removed lateral size reduction may be required Use drillings to fix with sccrews or wire if necessary Figure...